Skip to main content
OpenTrials
Completed

NCT Number: NCT05552963

A Study of Multi-electrode Circular Irreversible Electroporation (IRE) Catheter and Multi-Channel IRE Generator in Paroxysmal Atrial Fibrillation (AF)

The purpose of this study is to evaluate the long term off-Antiarrhythmic Drug (AAD) effectiveness of Biosense Webster, Inc. Irreversible Electroporation (BWI IRE) system in treatment of participants with symptomatic drug refractory paroxysmal atrial fibrillation (PAF).

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year–80 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Guangdong Provincial People's Hospital, Guangzhou, Guangdong, China

Loading trial locations.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Diagnosed with symptomatic paroxysmal atrial fibrillation (PAF) (Physician's note indicating recurrent self-terminating atrial fibrillation [AF]). At least one electrocardiographically documented AF episode within twelve (12) months prior to enrollment. Electrocardiographic documentation may include, but is not limited to, electrocardiogram (ECG), Holter monitor, or telemetry strip
  • Failed at least one Class I or Class III antiarrhythmic drug (AAD) as evidenced by recurrent symptomatic AF, contraindicated or intolerable to both Class I and Class III AAD
  • Able and willing to comply with all pre-procedure, post-procedure, and follow-up testing and visit requirements
  • Willing and capable of providing consent

Exclusion criteria

  • AF secondary to electrolyte imbalance, thyroid disease, or reversible or non-cardiac cause (Example, untreated documented obstructive sleep apnea and acute alcohol toxicity)
  • Previous left atrium (LA) ablation or surgery
  • Participants known to require ablation outside the pulmonary vein (PV) region (atrioventricular reentrant tachycardia, atrioventricular nodal reentry tachycardia, atrial tachycardia, atrial flutter of unknown origin, ventricular tachycardia and Wolff-Parkinson-White)
  • Previously diagnosed with persistent AF (greater than [>] 7 days in duration)
  • Severe dilatation of the LA (documented LAD >50 millimeters [mm] antero-posterior diameter by transthoracic echocardiography (TTE) within 6 month prior to enrollment)

Treatment and study plan

Multi-Channel Irreversible Electroporation (IRE) Generator

Device

The multi-channel IRE Generator is intended for use during cardiac Pulsed Field Ablation (PFA) therapy. This device is used in conjunction with a compatible ablation catheter to create a closed electrical circuit capable of delivering pulsed electrical field energy.

Other names: D-1417-01-I

Multi-Channel Circular IRE Catheter

Device

The multi-channel circular IRE Catheter is indicated for use in catheter-based cardiac electrophysiological mapping (stimulating and recording) and when used with an IRE Generator, for cardiac ablation.

Other names: D-1412-01-SI

Primary outcomes

  1. Percentage of Participants With Long-term Effectiveness

    Time frame: From Day 91 up to Day 365 post-procedure on Day 0

    Long-term effectiveness was defined as freedom from documented asymptomatic and symptomatic atrial fibrillation (AF), atrial tachycardia (AT), or atrial flutter (AFL; of unknown origin) episodes based on electrocardiographic data (greater than equal to [>=] 30 seconds on arrhythmia monitoring device) through the effectiveness evaluation period (Day 91 through Day 365 post index procedure) and freedom from the following failure modes : freedom from acute procedural failure, freedom from non-study catheter failure, freedom from repeat ablation failure, freedom from direct Current (DC) cardioversion failure, freedom from recurrence (captured on 12-lead electrocardiogram [ECG]) failure, and freedom from anti-arrhythmic drug failure. AFL of unknown origin was defined as all AFL except those Cavo-Tricuspid Isthmus (CTI) dependent AFL as confirmed by accepted electrophysiology (EP) maneuvers (for example, entrainment or activation mapping) in an EP study.

Secondary outcomes

  1. Percentage of Participants Experiencing Primary Adverse Event (PAE)

    Time frame: Within 7 days post-procedure on Day 0

    Percentage of participants experiencing PAE were reported. An AE is any untoward medical occurrence in a participant whether or not related to the investigational medical device. Primary AEs within seven days of the ablation procedure which used investigational devices per protocol, including the initial and repeat procedures were reported. PAEs included cardiac tamponade, perforation, myocardial infarction, stroke/cerebrovascular accident, thromboembolism, transient ischaemic attack, phrenic nerve injury/diaphragmatic paralysis, heart block, pulmonary vein stenosis, pulmonary oedema (respiratory insufficiency), vagal nerve injury/gastroparesis, pericarditis, major vascular access complication/bleeding, and atrio-esophageal fistula .

  2. Percentage of Participants Experiencing Serious Adverse Event (SAE) Within 7 Days, 8-30 Days and >30 Days of Initial Ablation Procedure

    Time frame: From day of procedure (Day 0) up to 12 months

    Percentage of participants with SAEs within 7 days (early-onset), 8-30 days (peri-procedural) and >30 days (late onset) of initial ablation procedure were reported. A SAE was any adverse event (AE) that resulted in a death or a serious deterioration in the health of the participant during the clinical trial, including a life-threatening illness or injury, a permanent impairment of a body structure or a body function, in-patient hospitalization or prolongation of existing hospitalization, medical or surgical intervention to prevent permanent impairment of a body structure or a body function; or resulted in fetal distress, foetal death or congenital abnormality, congenital anomaly, etc.

  3. Percentage of Participants With Acute Procedural Success

    Time frame: On the day of procedure (Day 0)

    Percentage of participants with acute procedural success were reported. Acute procedural success was defined as confirmation of entrance block in all clinically relevant targeted pulmonary veins (PVs) after adenosine/ isoproterenol challenge. Touching up with focal catheter was considered as acute procedural failure.

  4. Percentage of Participants With Acute Reconnection

    Time frame: On the day of procedure (Day 0)

    Percentage of participants with acute reconnection were reported. Acute reconnection was identified by adenosine/isoproterenol challenge among all clinically relevant targeted PVs and by participant.

  5. Percentage of Pulmonary Veins (PVs) With Acute Reconnection

    Time frame: On the day of procedure (Day 0)

    Percentage of PVs with acute reconnection were reported. Acute reconnection was identified by adenosine/isoproterenol challenge among all clinically relevant targeted PVs and by participant.

  6. Percentage of Participants With Pulmonary Vein (PV) Ablation

    Time frame: On day of procedure (Day 0)

    Percentage of participants with PV ablation by a non-study catheter (touch-up) among all clinically relevant targeted participants were reported.

  7. Percentage of Participants With Repeated Ablation

    Time frame: From the day of procedure (Day 0) up to 12 months

    Percentage of participants with repeated ablation within the 12 months follow up period, including timing (blanking period or after blanking) were reported. Repeat procedures for AF/AT/AFL of unknown origin plus recurrences during the blanking period (90 days post index procedure) were conducted with the investigational device for ablating PV reconnections. Repeat procedures performed after the blanking period were managed per investigator discretion using a commercially available ablation catheter and generator.

Sponsors and collaborators

Lead sponsor

Biosense Webster, Inc.

Industry

Registry information

Official study title

A Prospective, Multicenter, Single Arm With Performance Goal Study to Evaluate Safety and Effectiveness of Multi-electrode Circular IRE Catheter and Multi-Channel IRE Generator in Paroxysmal AF

Acronym: AFIRE

Important dates

Study start
2022
Primary completion
2024
Study completion
2024
First posted
Sep 23, 2022
Registry last updated
Jan 6, 2026

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.