University Hospitals of Derby and Burton
Derby, Derbyshire, DE3 0ED, United Kingdom
NCT Number: NCT05065229
On the neonatal unit in Derby, two types of probes are in routine use: Mindray 520 N and Mindray 521 N. Feedback from parents and staff show that there are concerns that the two probes given very different oxygen saturation readings and, often, do not agree with each other. This has raised concerns that infants' clinical care may be affected by the choice of probe. It is important to know if the two probes give similar results or not to ensure that infants get the appropriate monitoring and respiratory support as needed for good neonatal care. In this study, we will compare the reading made by the two probes and determine whether the readings of the two probes agree with each other and if any disagreement is such that clinical decision making is affected by the difference.
Looking for future studies?
Notify Me32 week–60 week
All sexes
Interventional
Not applicable
Derby, Derbyshire, DE3 0ED, United Kingdom
Continuous monitoring of oxygen saturation level is a key component of neonatal intensive care and NICE recommends that all neonatal services "ensure that systems are in place for preterm babies to have a target saturation level of 91% to 95%" and that this is monitored using "continuous pulse oximetry" (NICE Quality statement 4 in Quality Standard QS193: https://www.nice.org.uk/guidance/qs193/chapter/Quality-statement-4-Oxygen-saturation). Oxygen saturation monitoring is used to provide optimal respiratory support to preterm infants to ensure adequate oxygenation of tissues while preventing risks of conditions such as retinopathy of prematurity and bronchopulmonary dysplasia [1]. It is equally important in term born infants who require intensive care such as for determining adequate oxygenation for respiratory support and screening for congenital heart disease [2]. For these reasons, most infants in neonatal units are continuously monitored using pulse oximetry, a simple and painless test that measures blood oxygen levels by passing a small beam of light through the infant's hand or foot. This measures the changes in light absorption to calculate the levels of oxygenated and deoxygenated blood. To do this the light (or probe) has to be attached to the infant's hand or foot using a tie or a sticker. The probe must be attached firmly for the saturation monitor to pick up the correct readings. As neonatal skin is delicate and it is often difficult to stick objects to it, neonatal oxygen saturation probes are carefully designed. Many different types of saturation probes are in routine use in neonatal units. It is important to ensure that they give accurate and comparable readings. In the neonatal unit in Derby, two types of probes are in routine use: Mindray 520 N and Mindray 521 N. Feedback from parents and staff show that there are concerns that the two probes given very different oxygen saturation readings and, often, do not agree with each other. This has raised concerns that infants' clinical care may be affected by the choice of probe. It is important to know if the two probes give similar results or not to ensure that infants get the appropriate monitoring and respiratory support as needed for good neonatal care. In this study, we will compare the reading made by the two probes and determine whether the readings of the two probes agree with each other and if any disagreement is such that clinical decision making is affected by the difference.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Two oxygen saturation probes will be used in this study:
Mindray 520 N is a disposable oxygen saturation sensor for neonates and adults. It is a disposable, single-use sensor that is wrapped around the infant's arm or foot. Its ends stick together giving a firm, close contact with the skin.
Mindray 521 N is another disposable oxygen saturation sensor for neonates and adults that is used on the neonatal unit in routine practice. As Mindray 520 N and 521 N are CE marked and used within their intended purposes we do not require a letter of no objection from the MHRA for that usage. The Mindray probes will be used without modification and there are no safety issues to the patient. Therefore, a letter of no objection from the MHRA is not required and this is not a medical device study under the Medical Devices Directive.
Time frame: 12 months
Oxygen saturation readings using Minday 520 N and Minday 521 N probes simultaneously
Time frame: 12 months
clinical decisions made, such as giving supplemental oxygen to infants on the neonatal unit following oxygen saturation readings from Minday 520 N and Mindray 521 N
University of Nottingham
Other
Acronym: Ag-OS
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05762835
Congenital, Hereditary, and Neonatal Diseases and Abnormalities, Infant, Newborn, Diseases
Sacramento, California, United States
View Trial DetailsNCT05246709
Central Line Complication, Congenital, Hereditary, and Neonatal Diseases and Abnormalities
New York, United States
View Trial DetailsNCT04920175
Congenital, Hereditary, and Neonatal Diseases and Abnormalities, Infant, Newborn, Diseases
Ann Arbor, Michigan, United States
View Trial DetailsNCT06408064
Congenital, Hereditary, and Neonatal Diseases and Abnormalities, Infant, Newborn, Diseases
Bogotá, Colombia
View Trial Details