Skip to main content
OpenTrials
Not Yet Recruiting

NCT Number: NCT06810479

A Study Comparing Two Mandibular Advancement Devices in the Treatment of Sleep Apnea

The goal of this randomised, controlled cross-over study is to compare two mandibular repositioning devices (MRA) already on the market in the treatment of mild-to-moderate obstructive sleep apnea.

Patiënt will test the first MRA for 3 months, after a wash out period of 2 weeks they will test the second MRA for 3 months. It will be randomised what type of MRA will be tested first and second.

Not Yet Recruiting

Trial opening soon.

Get Notified

Key information

About this study

A mandibular repositioning appliance (MRA) is the primary treatment option for patients with mild to moderate obstructive sleep apnea (OSA), as well as for those with severe OSA who are intolerant to continuous positive airway pressure (CPAP) therapy or for whom surgical interventions are not viable. MRAs function by advancing the mandible, thereby increasing the volume of the upper airway and reducing its tendency to collapse during sleep. Various types of MRAs are available, and multiple classification systems can be employed to distinguish between these different types.

Mandibular repositioning appliances (MRAs) can be either custom-made or universal. Custom-made devices, which are typically more expensive, are fabricated in a dental laboratory using dental impressions. In contrast, prefabricated devices, often thermoplastic MRAs, are generally less costly and readily available over the counter.

Mandibular repositioning appliances (MRAs) can be classified as non-titratable, also known as monoblock devices, which have a fixed position, or titratable devices, which allow for gradual adjustment of the mandibular position until the desired therapeutic effect is achieved. Current guidelines recommend the use of titratable MRAs.

Titratable mandibular repositioning appliances (MRAs) can be further categorized into two types: midline traction devices, where the upper and lower components are connected at the front of the device, and bilateral thrust devices, where the upper and lower components are linked in the lateral or (pre-)molar regions.

Within the latter category, various designs exist, including devices that are adjustable on both sides using Hyrax screws and 3D-printed devices equipped with a series of lower components that allow for adjustments in mandibular position.

An example of an MRA adjustable with Hyrax screws is the SomnoDent® device (SomnoMed, Denton, Texas, USA). An example of a device utilizing a series of lower components for titration is the OrthoApnea appliance (ORTHOAPNEA S.L., Málaga, Spain), which features a specific attachment mechanism.

Although studies have already been published comparing different types of "bilateral thrust" devices, no studies to date have directly compared the categories mentioned above. The hypothesis of the investigators is that both appliances have similar effectiveness in the treatment of mild-to-moderate obstructive sleep apnea.

Primary objective:

Improvement of AHI, measured by polygraphy before treatment and after treatment with each MRA.

Secondary objective;

  • Peripheral oxygen saturation, measured by polygraphy before treatment and after treatment with each MRA
  • Average saturation
  • Lowest saturation
  • Oxygen desaturation index >3% (events/h)
  • Total duration with saturation < 90%
  • Epworth Sleepiness Scale, taken before treatment and after treatment with each MRA
  • Patient experience questionnaire, taken before treatment and after treatment with each MRA
  • Patient final choice of preferred MRA

Endpoints:

The investigators assess the objective improvement in OSA by comparing polygraphy results taken before and after treatment with each MRA. To evaluate the subjective effects of the MRA, the investigators compare the scores from the Epworth Sleepiness Scale. The participants subjective experience with each MRA type is measured using a patient experience questionnaire, along with noting the final preference for device type of the participants.

Study design:

  • Randomized, controlled cross-over study
  • Study population: Patients referred to the Department of Oral and Maxillofacial Surgery at ZOL Genk for Mandibular Repositioning Appliance (MRA) therapy, aged 18 years or older diagnosed with an Apnea-Hypopnea Index (AHI) between 5 and 30 events per hour.

Inclusion criteria

In order to be eligible to participate in this study, a subject must meet all of the following criteria:

  • Provide signed and dated informed consent
  • Males or females aged 18 and above
  • Apnea-Hypopnea Index (AHI) between 5 and 30 events per hour diagnosed by a polysomnography

Exclusion criteria

A potential subject who meets any of the following criteria will be excluded from participation in this study:

  • Previous surgery on the upper airways
  • Prior treatment of OSA (CPAP or MRA)
  • Presence of unstable cardiovascular conditions, neurological, mental, or psychiatric disorders
  • Insufficient dental or periodontal condition for a mandibular repositioning appliance (MRA)
  • Presence of temporomandibular joint dysfunction

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

In order to be eligible to participate in this study, a subject must meet all of the following criteria:

  • Provide signed and dated informed consent
  • Males or females aged 18 and above
  • Apnea-Hypopnea Index (AHI) between 5 and 30 events per hour diagnosed by a polysomnography

A potential subject who meets any of the following criteria will be excluded from participation in this study:

  • Previous surgery on the upper airways
  • Prior treatment of OSA (CPAP or MRA)
  • Presence of unstable cardiovascular conditions, neurological, mental, or psychiatric disorders
  • Insufficient dental or periodontal condition for a mandibular repositioning appliance (MRA)
  • Presence of temporomandibular joint dysfunction

Treatment and study plan

Polygraphy

Diagnostic Test

Polygraphy will be caried out at the patients home to evaluate each MRA after 3 monhts

Questionaire

Other

Epworth Sleepiness Scale

o Johns, Murray W. "A New Method for Measuring Daytime Sleepiness: The Epworth Sleepiness Scale." Sleep, vol. 14, no. 6, 1991, pp. 540-545.

Question

Other

Patient final choice of preferred MRA

Primary outcomes

  1. AHI

    Time frame: 3 monthts after use of first MRA (mandibular advancement device), 3 months after use of second MRA (mandibular advancement device)

    Improvement of AHI (apnea-hypopnea index), measured by polygraphy before treatment and after treatment with each MRA. The goal of the mandibular advancement device is to reduce the number of apneas and hypopneas per hour, apneas are periods when a person stops breathing and hypopneas are instances where airflow is blocked, causing shallow breathing. This is measured by a polygraphy-test overnight at the patiënts home.

Secondary outcomes

  1. Peripheral oxygen saturation 1

    Time frame: 3 monthts after use of first MRA, 3 months after use of second MRA

    Measured by polygraphy

    • Average saturation (measured in %)
    • Lowest saturation (measured in %)

    Oxygen saturation in percent is the fraction of oxygen-saturated haemoglobin relative to total haemoglobin (unsaturated + saturated) in the blood * 100%

  2. Peripheral oxygen saturation 2

    Time frame: 3 monthts after use of first MRA, 3 months after use of second MRA

    Measured by polygraphy

    o Oxygen desaturation index >3% (events/h)

    Desaturation episodes are defined as a decrease in the mean oxygen saturation of ≥3% for more than 10 seconds per hour

  3. Peripheral oxygen saturation 3

    Time frame: 3 monthts after use of first MRA, 3 months after use of second MRA

    Measured by polygraphy

    o Total duration with saturation < 90%

    The percentage of cumulative time with oxygen saturation below 90% in total sleep time.

  4. ESS

    Time frame: 3 monthts after use of first MRA, 3 months after use of second MRA

    Epworth Sleepiness Scale (questionaire)

    The minimum value is 0 and the maximum value is 24. A higher score means a worse outcome, indicating more excessive daytime sleepiness.

    The Epworth Sleepiness Scale is scored by adding up the individual scores for each of the eight questions. Each question is rated on a scale of 0 to 3, with 0 being "no chance of dozing" and 3 being "high chance of dozing." ter daytime sleepiness.

    Score range Interpretation 0-5 Lower normal daytime sleepiness 6-10 Normal daytime sleepiness 11-12 Mild excessive daytime sleepiness 13-15 Moderate excessive daytime sleepiness 16-24 Severe excessive daytime sleepiness

  5. Patient experience questionnaire

    Time frame: 3 monthts after use of first MRA, 3 months after use of second MRA

    Patient experience questionnaire, taken before treatment and after treatment with each MRA

    Oral Appliance Therapy Patient Experience Questionnaire (OATPEQ). The minimum value is 0 and the maximum value is 100. A higher score means a better outcome, indicating a more positive patient experience with oral appliance therapy.

  6. Final choice

    Time frame: after the use of each MRA for 3 months

    Patient final choice of preferred MRA.

    At the final visit, after using each MRA (type 1 and type 2) for three months (with a two-week washout period in between), the patient will choose their preferred device. The final choice will be noted down after oral questioning.

Study contacts

Contact information is provided by the study sponsor or research team.

Adriaan Blok, MD, DDS

CONTACT

[email protected]

+3289 32 50 50

Joeri Meyns, MD, DDS

CONTACT

[email protected]

+3289 32 50 50

Sponsors and collaborators

Lead sponsor

Ziekenhuis Oost-Limburg

Other

Registry information

Official study title

A Randomised, Controlled Cross Over Study Comparing Two Mandibular Advancement Devices in the Treatment of Mild-to-moderate Obstructive Sleep Apnea

Acronym: MRA OSA

Important dates

Study start
2025
Primary completion
2026
Study completion
2026
First posted
Feb 5, 2025
Registry last updated
Mar 21, 2025

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.