Centre de Recherche en Nutrition Humaine Auvergne
Clermont-Ferrand, 63000, France
NCT Number: NCT01995253
The aim of this study was to find functions for estimating energy expenditure in free-living conditions. This method was based on accelerometry data acquired from a smartphone worn in a trouser pocket. The developed functions have been compared to the estimations provided by two research devices named Armband and Actiheart.
Looking for future studies?
Notify Me18 year–60 year
All sexes
Interventional
Not applicable
Clermont-Ferrand, 63000, France
There is a growing interest in evaluating physical activity and energy expenditure (EE) to provide feedback to the user. The use of mass-market sensors such as accelerometers offers a promising solution for the general public due to the growing smartphone market over the last decade.
Thus, the proposed EE estimation function has been created using accelerometry data collected from 10 volunteers equipped with a smartphone and two research sensors (Armband and Actiheart) used to estimate EE during several controlled activities. The research sensors' data serves as reference during the creation and evaluation of the proposed function.
It has been evaluated with data of 6 other volunteers in free-living conditions. This new EE function using the smartphone technology is dedicated to light- and moderate-intensity activities, and we believe it can be a new way to help people controlling their daily physical activity level.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Volunteers were asked to perform several activities such as walking at different paces, running, sitting, standing still or taking public transportation for about 3h30 They wore 2 research sensors that estimate energy expenditure: Armband and Actiheart. They also wore a smartphone (in a front pant pocket) that collected accelerometry data.
Volunteers were asked to wear sensors during about 12 hours, one day. They wore 2 research sensors that estimate energy expenditure: Armband and Actiheart. They also wore a smartphone (in a front pant pocket) that collected accelerometry data.
Time frame: about 17Hz (duration: 3h30 in controlled conditions; 12 hours in free-living conditions)
Measures acquired by a smartphone (it contains several sensors, including a tri-axial accelerometer)
Time frame: one point recorded each minute for 3h30 in controlled conditions or 12 hours in free-living conditions
Sensor: Armband
Time frame: one point recorded each minute for 3h30 in controlled conditions or 12 hours in free-living conditions
Sensor: Actiheart
Institut National de Recherche pour l'Agriculture, l'Alimentation et l'Environnement
Other
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06023654
Accelerometry, Activity, Motor
Dublin, Ireland
View Trial DetailsNCT01995162
Accelerometry
Clermont-Ferrand, France
View Trial Details