CGuard Prime 80cm stent system
DeviceThis study is single arm looking at the technical success of the CGuard Prime 80cm stent system when used in conjunction with the FDA-cleared ENROUTE NPS during a TCAR procedure.
NCT Number: NCT06653387
The objective of this study is to evaluate acute device and technical success of the CGuard Prime™ Carotid Stent System (80cm) when used in conjunction with the Enroute NPS during Transcarotid Artery Revascularization procedures in the treatment of carotid artery stenosis in spatients at high risk for adverse events from carotid endarterectomy.
Interested in participating?
Request Info18 year–79 year
All sexes
Interventional
Not applicable
UC Davis Health, Sacramento, California, United States
This study is a prospective, multi-center, single arm pivotal study. The study shall not be blinded prior to, during or following the procedure. Patients undergoing transcarotid artery revascularization will be screened against the study inclusion/exclusion criteria. If the patient meets study eligibility requirements, they shall be invited to participate, provide informed consent and shall subsequently be assigned a study ID number.
Enrollment will be a minimum of 50 evaluable pivotal patients. A maximum of 20% of patients will be enrolled at any single site. The total enrollment accounts for an estimate that up to 2 patients will exit the study prior to the 30-day primary endpoint assessment.
An additional roll-in cohort of up to 2 patients per primary physician operator at each study site may also be accrued (maximum of 24 roll-in patients total, assuming one primary physician operator per site).
This study does not duplicate any current knowledge existing today on use of the CGuard Prime™ 80 used in conjunction with the ENROUTE NPS in the United States.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Candidates for participation in the study must meet all of the following general inclusion criteria.
Comorbid conditions:
Anatomic conditions:
Exclusion criteria
Patients are not eligible for the study if they have any of the following exclusion criteria.
This study is single arm looking at the technical success of the CGuard Prime 80cm stent system when used in conjunction with the FDA-cleared ENROUTE NPS during a TCAR procedure.
Time frame: From enrollment to end of follow-up at 1 year
Successful insertion of the delivery system, successful deployment of the CGuard Prime™ 80 stent, and successful retraction of the delivery system when used in conjunction with the FDA-cleared ENROUTE NPS during a TCAR procedure.
Time frame: From enrollment to end of follow-up at 1 year
Technical Success Rate is defined as the number of patients with at least one CGuard Prime™ 80 device successfully delivered and deployed with final residual diameter stenosis < 30% following final post-balloon dilatation (if performed) divided by the total number of patients where CGuard Prime™ 80 device deployment was attempted when used in conjunction with the FDA-cleared ENROUTE NPS during a TCAR procedure.
Time frame: From enrollment to 30-day follow-up
Acute device success for CGuard PrimeTM 80 Delivery System and Stent without experiencing death, stroke or MI through 30-day post-procedure when used in conjunction with the FDA-cleared ENROUTE NPS during a TCAR procedure.
Time frame: From enrollment to 30-day follow-up
Treatment Success Rate is defined as the number of patients who meet CGuard Prime™ 80 Technical Success Rate without experiencing death, stroke or MI through 30-day post-procedure, divided by the total number of patients where CGuard Prime™ 80 device deployment was attempted when used in conjunction with the FDA-cleared ENROUTE NPS during a TCAR procedure.
Time frame: From enrollment to 30-day follow-up
Time frame: From enrollment to 30-day follow-up
Time frame: From enrollment to 30-day follow-up
Time frame: From enrollment to 30-day follow-up
Time frame: From enrollment to 30-day follow-up
Time frame: From enrollment to 30-day follow-up
Time frame: From enrollment to 30-day follow-up
Time frame: From enrollment to 30-day follow-up
Time frame: From enrollment to end of follow-up at 1 year
Time frame: From enrollment to 30-day follow-up
Time frame: From enrollment to end of follow-up at 1 year
Time frame: From time of 30-day follow-up to end of follow-up at 1 year
Contact information is provided by the study sponsor or research team.
InspireMD
Industry
A Multicenter, Single-arm, Pivotal Study to Evaluate Acute Device and Technical Success of the CGuard Prime Carotid Stent System (80cm) When Used in Conjunction With the FDA-cleared ENROUTE Transcarotid Neuroprotection System (NPS) in Patients at High Risk for Adverse Events From Carotid Endarterectomy Undergoing Carotid Artery Stenting Via the Transcarotid Artery Revascularization (TCAR) Approach.
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07296965
Arterial Occlusive Diseases, Arteriosclerosis
Budapest, Hungary
View Trial DetailsNCT05800821
Arterial Occlusive Diseases, Brain Diseases
Minsk, Belarus
View Trial DetailsNCT06924593
Arterial Occlusive Diseases, Brain Diseases
Beijing, China
View Trial DetailsNCT06959628
Arterial Occlusive Diseases, Brain Diseases
Beijing, China
View Trial Details