OBJECTIVES:

The primary objective of this study is to assess the safety and efficacy of the Supralimus - Core™ Sirolimus Eluting Stent in de novo native vessel obstructive coronary artery disease.

STUDY DESIGN:

This is a single centre, prospective study. Approximately 105 patients were enrolled in the study. Patients were followed for twelve months post-procedure. All patients were to have a repeat angiography at 8 months.

STUDY POPULATION:

The study population consisted of approximately 105 patients with de novo native vessel obstructive coronary artery disease with no specific criteria. Patients from the daily practice were included. Patients had to meet all eligibility criteria for inclusion into the study.

ENDPOINTS:

The primary safety endpoint of the study is defined as Major Adverse Cardiac Events (MACE) at 30 days.

The primary efficacy endpoint is the in-stent binary restenosis rate at 8-month follow-up determined by off-line Quantitative Coronary Angiography.

The following secondary efficacy endpoints were assessed

* Angiographic success * Procedure success * Quantitative Coronary Angiography derived vessel parameters in-stent and 5 mm proximal and 5 mm distal from the edge of the stent: acute gain, MLD, % DS, late loss, mean diameter. In-stent pre-, post and at 8-month follow-up. * Clinically justified Target Lesion Revascularization (TLR) at 12 months

The following secondary safety endpoints were assessed:

* MACE until 12 months * Device related SAEs until 12 months * Angiographic stent thrombosis: Subacute (after procedure until 30 days) and Late (after 30 days until 12 months)

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Max Heart and Vascular Institute

New Delhi, 110017, India

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • The patient must be >= 18 years of age;
  • Symptomatic ischemic heart disease (CCS class 1 -4 , Braunwald class IB, IC, IIB, IIC, IIIB,IIIC) and/or objective evidence of myocardial ischemia;
  • Vessel size of >= 2.5 and <= 3.5mm.
  • Target lesions which can be covered by stent in a manner lesion stent ratio of at least 1.5.
  • Acceptable candidate for coronary artery bypass surgery (CABG);
  • Target lesion stenosis is >50% and <100% (TIMI flow I) (visual estimate);
  • The patient has been informed of the nature of the study agrees to its provisions and has provided written informed consent, approved by the appropriate Medical Ethics Committee (MEC) or Institutional Review Board (IRB).

Exclusion criteria

  • Women of childbearing potential;
  • Impaired renal function (creatinine > 2.0 mg/dl or 177 µmol/l);
  • Any patient who has a platelet count < 100,000 cells/mm3 or > 700,000 cells/mm3, a WBC of < 3,000 cells/mm3, or documented or suspected liver disease (including laboratory evidence of hepatitis);
  • Recipient of heart transplant;
  • Restenotic or lesion in graft.
  • Patient with a life expectancy less than 12 months;
  • Known allergies to aspirin, clopidogrel bisulphate (Plavix), ticlopidine (Ticlid), heparin or stainless steel;
  • Any significant medical condition which in the investigator's opinion may interfere with the patient's optimal participation in the study;
  • Currently participating in an investigational drug or another device study, or subject to inclusion in another investigational drug or another device study during follow-up.

Angiographic Exclusion criteria:

  • Unprotected left main coronary artery disease with >=50% stenosis;
  • Angiographic evidence of thrombus (thrombus larger than half the diameter of the vessel and/or requiring other interventions such as angiojet, exciser, thrombolysis, etc.);
  • Ejection fraction <= 30%;

Treatment and study plan

Supralimus-Core™

Device

Sirolimus Eluting Cobalt Chromium based coronary stent system

Supralimus™ Core™ Sirolimus eluting stent

Device

Supralimus™ Core™ Sirolimus eluting stent intended to treat coronary artery disease.

Primary outcomes

  1. Primary safety endpoint: Major Adverse Cardiac Events (MACE)

    Time frame: 30 days

  2. Primary efficacy endpoint: In-stent binary restenosis rate determined by off-line Quantitative Coronary Angiography.

    Time frame: 8 Month

Secondary outcomes

  1. Secondary safety endpoints: - MACE until 12 months, Device related SAEs until 12 months, Angiographic stent thrombosis: Subacute (after procedure until 30 days) and Late (after 30 days until 12 months)

    Time frame: 12 months

  2. Secondary efficacy endpoints: Angiographic, Procedure success; acute gain, MLD, % DS, LL, mean diameter; In-stent pre-,post,8-month follow-up; Clinically justified TLR at 12 months

    Time frame: 12 months

Sponsors and collaborators

Lead sponsor

Sahajanand Medical Technologies Limited

Industry

Registry information

Official study title

Safety And Efficacy Evaluation of Sirolimus Eluting Supralimus-Core™ Stent at MAX DDHV Institute in the Treatment of de Novo Native Coronary Artery Lesions

Acronym: Maximus

Important dates

Study start
2006
Primary completion
2007
Study completion
2008
First posted
Dec 19, 2008
Registry last updated
May 16, 2025

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.