ENSEAL X1 Curved Jaw
DeviceENSEAL X1 Curved Jaw is used for vessel transection according to instructions for use.
NCT Number: NCT04763421
This prospective, single-arm, multi-center study will collect clinical data in a post-market setting by procedure group (upper gastrointestinal [GI], lower GI, and gynecological). Investigators will perform each procedure using the device in compliance with their standard surgical approach and the ENSEAL X1 Curved Jaw and Generator G11 instructions for use.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
Gemelli Hospital, Rome, Italy
The primary objective of this study is to demonstrate the acceptable performance and safety of the ENSEAL X1 Curved Jaw and Generator G11 devices when used per the instructions for use.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
ENSEAL X1 Curved Jaw is used for vessel transection according to instructions for use.
Time frame: On the day of transection (Day 0)
Number of vessels with <= Grade 3 hemostasis based on hemostasis grading scale were reported. A 4-point grading scale was used to assess hemostasis in blood vessels. Grade 1: no bleeding at transection site; Grade 2: minor bleeding at transection site, no intervention needed; Grade 3: minor bleeding at transection site, mild intervention needed, use of compression, monopolar device and/or touch-ups with ENSEAL X1; or Grade 4: significant bleeding (example, pulsatile blood flow, venous pooling) requiring intervention such as extensive coagulation or use of additional hemostatic measures (example, hemoclips, staples, sutures, fibrin sealants, other advanced energy products).
Time frame: From Day 0 up to post-procedure follow up visit (up to 28 days)
Number of participants with device-related AEs were reported. Device-related AEs were those AEs identified as having a relationship of possibly, probably, or causally with the study devices.
Time frame: On the day of transection (Day 0)
Number of participants with adhesion removal or division using ENSEAL X1 device as assessed by Surgeon Satisfaction scale score were reported. Surgeon satisfaction scale score is a 5-point scale (very dissatisfied, dissatisfied, neither satisfied or dissatisfied, satisfied, or very satisfied) where surgeon rated the use of the device for adhesion removal or division by ENSEAL X1.
Time frame: On the day of transection (Day 0)
Number of participants with lymphatics bundles division using ENSEAL X1 device as assessed by Surgeon Satisfaction scale score were reported. Surgeon satisfaction scale score is a 5-point scale (very dissatisfied, dissatisfied, neither satisfied or dissatisfied, satisfied, or very satisfied) where surgeon rated the use of the device for lymphatic bundles by ENSEAL X1.
Time frame: On the day of transection (Day 0)
Number of participants with tissues bundles division using ENSEAL X1 device as assessed by Surgeon Satisfaction scale score were reported. Surgeon satisfaction scale score is a 5-point scale (very dissatisfied, dissatisfied, neither satisfied or dissatisfied, satisfied, or very satisfied) where surgeon rated the use of the device for tissues bundles by ENSEAL X1.
Time frame: On the day of transection (Day 0)
Number of participants with tissues grasping using ENSEAL X1 device as assessed by Surgeon Satisfaction scale score were reported. Surgeon satisfaction scale score is a 5-point scale (very dissatisfied, dissatisfied, neither satisfied or dissatisfied, satisfied, or very satisfied) where surgeon rated the use of the device for tissues grasping by ENSEAL X1.
Time frame: On the day of transection (Day 0)
Number of participants with tissues cutting using ENSEAL X1 device as assessed by Surgeon Satisfaction scale score were reported. Surgeon satisfaction scale score is a 5-point scale (very dissatisfied, dissatisfied, neither satisfied or dissatisfied, satisfied, or very satisfied) where surgeon rated the use of the device for tissues cutting by ENSEAL X1.
Time frame: On the day of transection (Day 0)
Number of participants with tissues dissection using ENSEAL X1 device as assessed by Surgeon Satisfaction scale score were reported. Surgeon satisfaction scale score is a 5-point scale (very dissatisfied, dissatisfied, neither satisfied or dissatisfied, satisfied, or very satisfied) where surgeon rated the use of the device for tissues dissection by ENSEAL X1.
Time frame: On the day of transection (Day 0)
Number of vessels with hemostasis (Grade 1 to 4) based on hemostasis grading scale were reported. A 4-point grading scale was used to assess hemostasis in blood vessels. Grade 1: no bleeding at transection site; Grade 2: minor bleeding at transection site, no intervention needed; Grade 3: minor bleeding at transection site, mild intervention needed, use of compression, monopolar device and/or touch-ups with ENSEAL X1; or Grade 4: significant bleeding (example, pulsatile blood flow, venous pooling) requiring intervention such as extensive coagulation or use of additional hemostatic measures (example, hemoclips, staples, sutures, fibrin sealants, other advanced energy products).
Time frame: On the day of transection (Day 0)
Percentage of Grade 4 vessel transections requiring hemostasis measures were planned to be reported. Data was not collected and analyzed for this outcome measure because there were no hemostatic grade 4 vessel transections.
Ethicon Endo-Surgery
Industry
A Prospective, Single-Arm Multi-Center Study of the ENSEAL X1 Curved Jaw Tissue Sealer and Generator G11 in Upper Gastrointestinal, Lower Gastrointestinal, and Gynecological Procedures
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.