Skip to main content
OpenTrials
Recruiting

NCT Number: NCT06839898

A Prospective, Randomized Clinical Study of Two Phakic Toric Implantable Lenses

Primary Objective: To compare the efficacy and the residual refractive error of EYECRYLTM Phakic toric versus Visian® Toric ICL in moderate to high myopic patient with co-existing astigmatism. Secondary Objectives: To evaluate and compare the safety of EYECRYLTM Phakic toric versus Visian® Toric ICL in moderate to high myopic patients with co-existing astigmatism.

Recruiting

Interested in participating?

Request Info

Key information

Age range

21 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Precise Vision Augentagesklinik Greven, Münster, North Rhine-Westphalia, Germany

Loading trial locations.

About this study

Phakic intraocular lenses are clear implantable lenses that are surgically placed either in anterior chamber (AC) or posterior chamber (PC) without removing the natural lens, enabling light to focus on the retina for improved uncorrected visual acuity. Phakic intraocular lenses demonstrate high optical quality and potential gain in visual acuity in myopic patients due to retinal magnification. Toric version of phakic intraocular lens is intended to correct both myopia and astigmatism.1

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Patients 21 years old or older.
  • Calculated IOL Power is within the range of the investigational IOLs
  • Corneal Cylindrical error within the range defined in the clinical investigation plan
  • Subject has monocular UCVA 0.5 LogMAR or worse
  • Subject has had a stable refraction (±0.5D; ±1.0D for higher refractive errors), as expressed by manifest refraction spherical equivalent (MRSE) for a minimum 12 months prior to surgery, verified by consecutive refractions and/or medical records or prescription history.
  • Subject, who is a current contact lens wearer, needs to demonstrate a stable refraction (±0.5D) expressed as MRSE, on two consecutive examination dates and stability of the refraction is determined by the following criteria:
  • Contact lenses were not worn for at least 2 weeks or 3 days prior to the first refraction.
  • Two refractions were performed at least 7 days apart.
  • Subject, who is expected to have residual postoperative cylindrical refractive error of ≥1D, has been given the opportunity to experience his/her best spectacle vision with the anticipated correction.
  • Expected dilated pupil size at least large enough to visualize the axis marking.
  • Patients willing to attend all follow-up appointments
  • Patients must sign and be given a copy of the written Informed Consent form

Exclusion criteria

  • Subject with acute and chronic disease or illness that would increase the operative risk or confound the outcomes of the evaluation.
  • Subject taking systematic medication that can confound the outcome of the study or increase the risk to the subject
  • Subject with ocular condition that may predispose the subject to future complications
  • Subject with previous intraocular or corneal surgery
  • Subject with less than the minimum endothelial cell density 2000 cells/mm² at the time of enrollment
  • Pregnant or planning to become pregnant, or is lactating during the course of the evaluation
  • Other condition associated with fluctuation of hormones
  • ACD measured from the endothelium lower than 2.8 mm
  • Concurrent participation in another drug or device evaluation.
  • Any cataract of any grade.
  • Coefficient of variation of endothelial cell area >0.45
  • Percent Hexagonality of endothelial cell shape ≤ 45%
  • Monocular subject
  • Vulnerable subjects as defined in section 12.3.10

Treatment and study plan

EYECRYLTM Phakic Toric Intraocular Lens Treatment Arm

Device

The patients will be implanted with Eyecryl Phakic IOL at this arm based on randomization.Phakic intraocular lenses are clear implantable lenses that are surgically placed either in anterior chamber (AC) or posterior chamber (PC) without removing the natural lens, enabling light to focus on the retina for improved uncorrected visual acuity. Phakic intraocular lenses demonstrate high optical quality and potential gain in visual acuity in myopic patients due to retinal magnification. Toric version of phakic intraocular lens is intended to correct both myopia and astigmatism.

Visian® Toric ICL Treatment Arm

Device

The patients will be implanted with Visian® Toric Implantable Contact Lens at this arm based on randomization. Phakic intraocular lenses are clear implantable lenses that are surgically placed either in anterior chamber (AC) or posterior chamber (PC) without removing the natural lens, enabling light to focus on the retina for improved uncorrected visual acuity. Phakic intraocular lenses demonstrate high optical quality and potential gain in visual acuity in myopic patients due to retinal magnification. Toric version of phakic intraocular lens is intended to correct both myopia and astigmatism.

Primary outcomes

  1. The mean residual refractive error

    Time frame: 6 Month

    The mean residual refractive error in the study lens population that is equivalent to the mean residual refractive error of the control lens within +/- 0.50 Diopters at the 6-months post-op visit.

Study contacts

Contact information is provided by the study sponsor or research team.

BHARGAV D JOSHI, M.Sc.

CONTACT

[email protected]

917966823000 ext. 203

Hatice B Deveci Summer, B.Sc

CONTACT

[email protected]

0491739106424

Sponsors and collaborators

Lead sponsor

Biotech Healthcare Holding Gmbh

Industry

Registry information

Official study title

A Prospective, Randomized Clinical Study of Two Phakic Toric Implantable Lenses to Compare Outcomes in Patients With Moderate to High Myopia and Astigmatism

Important dates

Study start
2021
Primary completion
2025
Study completion
2027
First posted
Feb 21, 2025
Registry last updated
Feb 21, 2025

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.