Zepto System
DeviceAnterior Capsulotomy using the Zepto System.
Other names: Zepto
NCT Number: NCT02890303
This study will evaluate outcome in subjects who have elected to have Zepto capsulotomies during cataract surgery with phacoemulsification.
Looking for future studies?
Notify Me22 year and older
All sexes
Interventional
Not applicable
This study will evaluate outcome in subjects who have elected to have Zepto capsulotomies during cataract surgery with phacoemulsification to evaluate safety and effectiveness. The primary effectiveness endpoint is a complete capsulotomy in at least 95 percent of the cases. The primary safety endpoint is posterior capsular rupture and virtuous loss in 4 percent or less of the subjects. Other parameters to be captured during the study include anterior capsule tears, corneal touch, capsulotomy diameter, contraption of the Zepto capsulotomy, size of the corneal incision pre and post Zepto, interocular lens contraption and evaluation of zonular stability and the incidence and severity of adverse events. The criteria for patient success will be accessed based on the successful completion of a 360 degree capsulotomy without tissue bridges and no posterior capsule rupture and vitreous loss. The criteria for study success will be accessed based on a greater than or equal to 95 percent of the cases having a complete 360 degree capsulotomy without tissue bridges and less than 4 percent of subjects with posterior capsule rupture and vitreous loss.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Anterior Capsulotomy using the Zepto System.
Other names: Zepto
Time frame: During surgery
A successful complete Zepto capsulotomy is defined in this protocol to be one that results in a complete 360 degree capsulotomy without any residual tissue bridges visible to the surgeon. If there are such tissue bridges, the surgeon completes the capsulotomy manually.
The primary effectiveness endpoint was defined as :Complete capsulotomy (target ≥ 95% of cases).
Mynosys Cellular Devices, Inc.
Industry
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07735000
Age Related Cataract, Cataract
Peshawar, KPK, Pakistan
View Trial DetailsNCT07605260
Cataract, Eye Diseases
Islamabad, Punjab Province, Pakistan
View Trial DetailsNCT06428955
Cataract, Eye Diseases
Indianapolis, Indiana, United States
View Trial DetailsNCT06111222
Cataract, Eye Diseases
Heidelberg, Germany
View Trial Details