Skip to main content
OpenTrials
Active, Not Recruiting

NCT Number: NCT04765176

A PMCF Study in Patients With Infrarenal Aortic Aneurysm Treated With the E-tegra Stent Graft System

The EASY post-market clinical follow-up study is undertaken to demonstrate safety and clinical performance of the E-tegra Stent Graft System used in endovascular treatment of infrarenal aortic aneurysm.

Active, Not Recruiting

This study is active but is not currently recruiting participants.

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Observational

Primary location

Rijnstate Hospital

Arnhem, 6815, Netherlands

About this study

In this study, patients will be observed who receive an E-tegra Stent Graft for the treatment of infrarenal aortic aneurysm. The E-tegra Stent Graft will be implanted at the discretion of the treating physician.

Participating physicians will provide their observations collected during routine care for patients they have decided to treat with the E-tegra stent graft. Informed consent of the patients to the use of their clinical records for study purposes will be obtained before their data will be collected in the post-market clinical follow-up study. All patients will be asked to complete questionaires focussing on the health status (HS) (SF-12) and Quality of Life (QoL) (WHOQOL-BREF).

The period of data collection will be approximately 60 months from the date of intervention for each patient. Source document verification will be performed on 100% of the patients; data from all visits will be reviewed and verified against existing source documents. Complete DICOM image files of the CT scans as well as other imaging files (e.g. CEUS, MRT) will be sent to a CoreLab for independent second evaluation. There is no CoreLab screening before inclusion. All adverse events defined prior to study start, will be adjudicated by the Clinical Evaluation Committee (CEC).

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Age ≥ 18
  • Patient must have an infrarenal aortic aneurysm with diameter ≥ 50 mm in females and ≥ 55 mm in males, or infrarenal aortic aneurysm with 40-50 mm that has increased in size by ≥ 1 cm per year
  • Patient is elegible for treatment inside the instructions for use of the E-tegra Stent Graft System
  • Patient is able and willing to undergo follow-up imaging and examinations prior to discharge from the hospital, at 30 days and 12 months, and annually thereafter until 5 years follow-up
  • Patient understands and has signed the Informed Consent Form prior to intervention
  • Patient has a life expectancy of at least 5 years

Exclusion criteria

  • Patient with severe calcification or thrombi in the proximal sealing zone
  • Patient with infectious aneurysm
  • Patient with inflammatory aneurysm
  • Patient with pseudoaneurysm
  • Patient with symptomatic aneurysm
  • Patient with ruptured or traumatic aneurysm
  • Patient with suprarenal, juxtarenal, or pararenal aneurysm
  • Patient with aortic dissection
  • Patient with a reversed conical neck that is defined as a > 3 mm distal increase over a 15 mm length
  • Patient in which the E-tegra Stent Graft System is used in combination with proximal or distal extenders of another company.
  • Patient who is planned to be treated with an adjunctive aortic bare metal stent or a fenestrated stent graft
  • Patient who is planned to be treated with a chimney / chimneys in the renal or visceral vessels
  • Patient who is planned to be treated with an iliac branch device or parallel grafts in the iliac vessels
  • Patient with genetic connective tissue disease (e.g. Marfan syndrome or Ehlers-Danlos syndrome)
  • Patient with eGFR < 45 ml/min/1.73 m2 before the intervention
  • Patient had or planned to have a major surgical or interventional procedure within 30 days before or 30 days after the planned implantation of the E-tegra Stent Graft System
  • Patient with other medical condition that may cause the patient to be non-compliant with the protocol, confound the results, or is associated with a limited life expectancy of less than five years (i.e. heart failure, active malignancy (progressive, stable or partial remission))
  • Patient who has been enrolled in another active clinical trial that does not allow inclusion in this trial

Treatment and study plan

endovascular repair

Device

Endovascular repair of the infrarenal aorta using a AAA stent graft.

Primary outcomes

  1. Mortality

    Time frame: 30-day

    Rate of all-cause mortality

Secondary outcomes

  1. Mortality

    Time frame: 24 hours, 12, 24, 36, 60 months

    Rate of all-cause mortality

  2. Aneurysm-related mortality

    Time frame: 30-day, 12, 24, 36, 60 months

    Rate of aneurysm-related mortality

  3. Aneurysm rupture-related mortality

    Time frame: 30-day, 12, 24, 36, 60 months

    Rate of aneurysm rupture-related mortality

  4. Technical success

    Time frame: 24 hours

    Rate of patients with device technical success

  5. Clinical success

    Time frame: 12 months

    Rate of patients with clinical success

  6. Reintervention

    Time frame: 30-day, 12, 24, 36, 60 months

    Rate of patients with any reintervention

  7. Reintervention-free survival

    Time frame: 12 months

    Rate of patients with reintervention-free survival

  8. Primary limb patency

    Time frame: 30-day, 12, 24, 36, 60 months

    Rate of patients with primary E-tegra Stent Graft limb patency

  9. Secondary limb patency

    Time frame: 30-day, 12, 24, 36, 60 months

    Rate of patients with secondary E-tegra Stent Graft limb patency

  10. Stable aneurysm size

    Time frame: 12, 60 months

    Rate of patients with stable aneurysm size

  11. Decreasing aneurysm size

    Time frame: 12, 60 months

    Rate of patients with decreasing aneurysm size on CTA scan (≤ 5 mm in maximum diameter)

  12. Increasing aneurysm size

    Time frame: 12, 60 months

    Rate of patients with aneurysm growth on CTA scan (≥ 5 mm in maximum diameter)

  13. Major adverse events

    Time frame: 30-day, 12, 24, 36, 60 months

    Rate of patients with major adverse events (aneurysm-related death, aneurysm rupture, new myocardial infarction requiring intervention (percutaneous transluminal coronary angioplasty, bypass), new disabling stroke (mRS ≥ 2), visceral ischemia (bowel ischemia with surgical/endovascular intervention or submission to ICU or bowel necrosis with surgical/endovascular intervention or submission to ICU), new hepatic infarction, new chronic (> 90 days) renal insufficiency/renal failure requiring dialysis, new permanent (> 30 days) paraplegia (modified Tarlov Scale ≤ 2), new permanent (> 30 days) paraparesis (modified Tarlov Scale 3 or 4), lower limb ischemia (increase in Rutherford classification)

  14. Endoleak Type Ia

    Time frame: 12, 60 months

    Rate of patients with Type Ia endoleak

  15. Endoleak Type Ib

    Time frame: 12, 60 months

    Rate of patients with Type Ib endoleak

  16. Endoleak Type II

    Time frame: 12, 60 months

    Rate of patients with Type II endoleak

  17. Endoleak Type III

    Time frame: 12, 60 months

    Rate of patients with Type III endoleak

  18. Endoleak Type IV

    Time frame: 12, 60 months

    Rate of patients with Type IV endoleak

  19. Endoleak of unknown origin

    Time frame: 12, 60 months

    Rate of patients with endoleak of unknown origin

  20. Stent graft migration

    Time frame: 12, 60 months

    Rate of patients with stent graft migration > 10 mm

  21. Dislodgement

    Time frame: 30-day, 12, 24, 36, 60 months

    Rate of patients with stent graft dislodgement (full component separation)

  22. Stent fracture

    Time frame: 12, 60 months

    Rate of patients with stent fracture

  23. Stent graft infection

    Time frame: 30-day, 12, 24, 36, 60 months

    Rate of patients with stent graft infection

  24. Health status

    Time frame: 6, 12, 48 to 60 months

    Rate of patients with the same level of health status as prior to surgery

  25. QoL

    Time frame: 6, 12, 48 to 60 months

    Rate of patients with the same level of QoL as prior to surgery

Sponsors and collaborators

Lead sponsor

JOTEC GmbH

Industry

Registry information

Official study title

A European Post-Market Clinical Follow-up Study (PMCF) in Patients With Infrarenal Aortic Aneurysm Undergoing Endovascular Stenting With the E-tegra Stent Graft System

Acronym: EASY

Important dates

Study start
2021
Primary completion
2023
Study completion
2029
First posted
Feb 21, 2021
Registry last updated
Jul 25, 2024

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.