Completed

NCT Number: NCT02981446

A Phase III Study Assessing the Safety and Efficacy of DE-117 Ophthalmic Solution Compared With Latanoprost Ophthalmic Solution in Subjects With OAG or OHT

The purpose of this study is to investigate the intraocular pressure-lowering effect and the safety of DE-117 ophthalmic solution compared with Latanoprost ophthalmic solution in subjects with open angle glaucoma or ocular hypertension.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Phase 3

Primary location

Singapore

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Patients with open angle glaucoma or ocular hypertension in both eyes

Exclusion criteria

  • Patients at risk of progression of visual field loss
  • Patients with severe visual field defect
  • Patients with any diseases that preclude participation in this study for safety reasons

Treatment and study plan

DE-117

Drug

DE-117 ophthalmic solution will be taken one drop, once daily for 3 months in both eyes.

Latanoprost ophthalmic solution

Drug

Latanoprost ophthalmic solution will be taken one drop, once daily for 3 months in both eyes.

Other names: Xalatan

Primary outcomes

  1. Mean Diurnal IOP at Month 3

    Time frame: Month 3 (average of IOP at 3 time points: 09:00, 13:00, 17:00)

    The IOP (mmHg) measured in the study eye (identified at Day 1 [baseline]) was the efficacy measure for this study. The IOP was measured using a calibrated Goldmann applanation tonometer preferably by the same Investigator (operator) and the same authorized study staff (recorder) during the study for each subject.

Secondary outcomes

  1. IOP at 9 Timepoints (First Key Secondary Efficacy Endpoint)

    Time frame: 09:00, 13:00, and 17:00 at Week 1, Week 6, and Month 3.

    The IOP (mmHg) measured in the study eye (identified at Day 1 [baseline]) was the efficacy measure for this study. The IOP was measured using a calibrated Goldmann applanation tonometer preferably by the same Investigator (operator) and the same authorized study staff (recorder) during the study for each subject.

  2. Mean Diurnal IOP at Week 1 (Second Key Secondary Endpoint)

    Time frame: Week 1

    The IOP (mmHg) measured in the study eye (identified at Day 1 [baseline]) was the efficacy measure for this study. The IOP was measured using a calibrated Goldmann applanation tonometer preferably by the same Investigator (operator) and the same authorized study staff (recorder) during the study for each subject.

Sponsors and collaborators

Lead sponsor

Santen Pharmaceutical Co., Ltd.

Industry

Registry information

Official study title

A Phase III, Randomized, Observer-Masked, Active-Controlled, Parallel-Group, Multinational and Multicenter Study Assessing the Safety and Efficacy of DE-117 Ophthalmic Solution 0.002% Compared With Latanoprost Ophthalmic Solution 0.005% in Subjects With Open-Angle Glaucoma or Ocular Hypertension- PEONY Study

Important dates

Study start
2017
Primary completion
2019
Study completion
2019
First posted
Dec 5, 2016
Registry last updated
Mar 15, 2024

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)