Skip to main content
OpenTrials
Completed

NCT Number: NCT01036165

A Multicenter, Open-label, RebiSmart™ Autoinjector Ease of Use Study

The purpose of this study is to test the RebiSmart™ for

* ease of use * multiple domains related to subject's acceptability and satisfaction * reliability of the correct function for self-injection of Rebif® 44 mcg sc tiw in subjects with RMS.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year–65 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Phase 3

Primary location

EMD Serono, Inc.

Rockland, Massachusetts, 02370, United States

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Male and female subjects, 18-65 years of age, inclusive, at the time of informed consent signature
  • RMS diagnosed according to the McDonald criteria
  • Currently receiving Rebif® 44mcg sc tiw using manual injections and/or Rebiject II autoinjector for greater than or equal to twelve weeks
  • Capable of self-injecting using the RebiSmart™ autoinjector. Self- injecting is defined as being able to make 2 of the 3 weekly injections without assistance.
  • Be willing and able to comply with the study procedures for the duration of the trial
  • Have given written informed consent and signed Health Insurance Portability and Accountability Act (HIPAA) Authorization before any study- related activities are carried out
  • Female subjects must not be either pregnant or breast-feeding and must lack childbearing potential, as defined by either:
  • Being post-menopausal or surgically sterile, or using a highly effective method of contraception (defined as a method that results in a low failure rate (i.e. less than 1% per year) when used consistently and correctly, and includes for instance, implants, injectables, combined oral contraceptives*, some intrauterine devices, sexual abstinence or vasectomised partner)
  • Female subjects of childbearing potential must have a negative pregnancy test at Screening and Study Day 1 to be included in the trial. A urine pregnancy test will also be done at the Week 12/Exit visit
  • Note for subjects using a hormonal contraceptive method: No formal drug interaction studies have been carried out with Rebif®. As interferons have been reported to exert an inhibitory activity on hepatic microsomal enzymes, it is unlikely that the clearance of oral contraceptives would increase and result in decreased efficacy. In over 10,000 patient years of clinical trial experience with Rebif®, there has never been any indication of an interaction with oral contraceptives.

Exclusion criteria

  • Have used any other injectable medications (e.g. for pain) on a regular basis during the week prior to Screening or throughout the duration of the trial (the administration of a single injection for treatment or prophylaxis of a condition unrelated to MS or Rebif® therapy (e.g., influenza or pneumococcus vaccination) will be acceptable)
  • Have received MS therapy other than Rebif® within twelve weeks prior to Screening or at any time during the trial (e.g., other disease modifying drugs, Rebif® New Formulation, combination therapy, immunomodulatory and/or immunosuppressive agents, including but not limited to any other interferon (Avonex/Betaseron/Extavia), glatiramer acetate (Copolymer I), cyclophosphamide, cyclosporine, methotrexate, linomide, azathioprine, mitoxantrone, teriflunomide, laquinimod, cladribine, fingolimod (FTY720), total lymphoid irradiation, anti-lymphocyte monoclonal antibody treatment (e.g. natalizumab, alemtuzumab/Campath, anti-CD4), Intravenous immunoglobulin (IVIg), cytokines or anti-cytokine therapy) and telbivudine
  • Have inadequate liver function, defined by a alanine aminotransferase (ALT) > 2.5x upper limit of normal (ULN), or alkaline phosphatase > 2.5x ULN, or total bilirubin > 2.5x ULN
  • Have inadequate bone marrow reserve, defined as a total white blood cell count < 3.0x 109/L, platelet count < 75x109/L, hemoglobin < 100g/L
  • Have complete transverse myelitis or simultaneous-onset bilateral optic neuritis
  • Have a history of alcohol or drug abuse
  • Have thyroid dysfunction
  • Have moderate to severe renal impairment
  • Have a major medical or psychiatric illness that in the opinion of the investigator creates undue risk to the subject or could affect compliance with the study protocol
  • Have a history of seizures not adequately controlled by treatment
  • Have serious or acute cardiac disease, such as uncontrolled dysrhythmias, uncontrolled angina pectoris, cardiomyopathy, or uncontrolled congestive heart failure
  • Have, in the opinion of the investigator, major visual, physical or cognitive impairment that would preclude the subject from self-injecting with the RebiSmart™ autoinjector
  • Have a known hypersensitivity or allergy to interferon-beta or any of the excipients
  • Have participated in another clinical trial within the past thirty days
  • Are pregnant or attempting to conceive
  • Have previously used a RebiSmart™ autoinjector

Treatment and study plan

RebiSmart™

Device

The RebiSmart™ autoinjector contains Rebif® 132 mcg multidose cartridges for sc injection.

Primary outcomes

  1. The Primary Endpoint is the Proportion of RMS Subjects Rating the RebiSmart™ Autoinjector as 'Easy to Use' or 'Very Easy to Use' for Self-injection in a User Trial Questionnaire.

    Time frame: at 12 Weeks

    Data from the User Trial Questionnaire-B, Question 13 (Overall, how do you rate your experience with using the injection device). Mean and confidence intervals refer to proportion of subjects responding positively to question. Missing values were replaced with worst case response.

Secondary outcomes

  1. Multiple Secondary Endpoints Will be Assessed, Based on Questions From the User Trial Questionnaire Related to the RebiSmart™ Autoinjector Use-related Outcomes.

    Time frame: at Week 12

    The User Trial Questionnaire B was administered at Week 6 and Week 12 to assess the ease of use, functional reliability, overall satisfaction, satisfaction with device attributes, convenience, safety and portability of the Rebismart. Means and confidence intervals refer to the proportion of subjects responding positively, based on the number of non-missing values for each question. Secondary endpoints presented for decriptive purposes only thus no statistical analysis performed.

Sponsors and collaborators

Lead sponsor

EMD Serono

Industry

Registry information

Official study title

A Twelve-week, Phase IIIb, Open-label, Single-arm, Multicenter Trial to Evaluate Ease of Use of an Electronic Autoinjector (RebiSmart™) for Self-injection in Subjects With Relapsing Multiple Sclerosis (RMS) Treated With Rebif® 44mcg Subcutaneously (sc) Three Times a Week (Tiw)

Acronym: Performs

Important dates

Study start
2010
Primary completion
2010
Study completion
2010
First posted
Dec 21, 2009
Registry last updated
Aug 8, 2013

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.