Skip to main content
OpenTrials
Not Yet Recruiting

NCT Number: NCT06505434

A Dynamic Study of Pupil Diameter After Artificial Lens Implantation in Patients With High Myopia

Age-related cataract remains the leading cause of blindness in developing countries. And, with the aging of the population in these countries, the number of cataract patients will continue to grow. With accurate biological measurements and the implantation of appropriate IOLs, most cataract patients can achieve good distance vision after surgery. However, it should not be overlooked that the current global prevalence of myopia is over 28.3% and is expected to reach 49.8% by 2050, while the rate of high myopia will increase from the current 4.0% to 9.8%. The prevalence of cataracts is significantly higher in the highly myopic population than in the orthoptic population.

The pupil is an important factor to be evaluated during the selection of an artificial lens (Intraocular lens, IOL), especially a functional IOL. It has been shown that the diameter and sensitivity of the pupil in patients with high myopia are also significantly different from those in the orthopneic population, and that there is a correlation with the adjustment status and refractive error. The purpose of this study is to investigate the following: 1. Whether the change of refractive status before and after IOL implantation in highly myopic cataract patients will lead to the change of pupil physiological characteristics, and whether the modification of preoperative measurement parameters can expand the population of myopic patients who can be reasonably applied to the functional IOL and obtain a high degree of satisfaction from patients. 2. Pupil diameter under a single fixed light source is a rough assessment for the screening of the population for functional IOLs, and this study was conducted in a single fixed light source. In this study, we measured the maximum value of pupil diameter, minimum value of pupil diameter, and rate of change of pupil diameter under bright vision and dark vision, and analyzed the correlation between the above three parameters and visual quality to further optimize the objective index of pupil diameter for the screening of functional IOL applicants.

Objectives of the study

1. To observe the dynamic changes of pupil diameter and its visual quality before and after lens extraction combined with IOL implantation in myopic patients, and to analyze the correlation between the changes of pupil diameter and visual quality; 2. To explore the patterns of refractive error and pupil biometric changes in myopic patients before and after IOL implantation, and to make corrections for the evaluation of preoperative biometric indexes for reference.

Not Yet Recruiting

Trial opening soon.

Get Notified

Key information

Age range

50 year–90 year

Sex eligibility

All sexes

Study type

Observational

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

(1) a diagnosis of myopia: equivalent spherical lens extent (SE) SE ≤ -0.0 D when the eye is relaxed in accommodation; (2) a diagnosis of cataract; (3) surgical treatment with sequential lens ultrasonoemulsification combined with monofocal IOL implantation in both eyes at our hospital; and (4) consent to participate and cooperate in this study.

Exclusion criteria

(1) Symptoms of acute eye diseases, such as eye redness, eye pain, and increased eye discharge; (2) Other binocular eye diseases that seriously affect visual function, such as amblyopia, glaucoma, diabetic retinopathy, severe age-related macular degeneration and retinal detachment; (3) Intra-operative or post-operative complications from cataract surgery; combined with other ophthalmologic surgeries; and any other ophthalmologic surgeries in both eyes during the follow-up period; (4) History of injuries; (5) Inability to understand the informed consent; and (6) Inability to communicate. ) history of trauma; (5) inability to understand the informed consent form and inability to communicate.

Treatment and study plan

cataract surgery

Procedure

Phaco + IOL Implantation

Primary outcomes

  1. pupil size

    Time frame: 1 week ,1 month, 3 months

    pupil size before and after surgery

Sponsors and collaborators

Lead sponsor

Shanghai Eye Disease Prevention and Treatment Center

Other

Registry information

Important dates

Study start
2024
Primary completion
2025
Study completion
2026
First posted
Jul 17, 2024
Registry last updated
Jul 17, 2024

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.