Test lens
DeviceContact lens
Other names: Invigor I lens
NCT Number: NCT03499067
Evaluation of the clinical performance of an investigational silicone-hydrogel contact lens (test) compared to a marketed lens (control), when worn on a daily basis for 1 month.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Clinical Research Center, University of California, Berkeley, Berkeley, California, United States
Evaluation of the clinical performance of an investigational silicone-hydrogel contact lens (test) compared to a marketed silicone- hydrogel contact lens (control), when worn on a daily basis for 1 month.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Contact lens
Other names: Invigor I lens
Contact lens
Other names: Clariti lens
Time frame: Baseline
Lens surface wettability was measured on a scale of 0-4, 0.25 steps (0 Very Poor: Immediately displaying non-wetting areas on the lens surface, immediate drying time, 1 Poor: Irregular surface appearance, drying time << blink time, 2 Acceptable: Smooth surface appearance immediately, after the blink becoming irregular after a while, drying time ≤ blink time, 3 Good: Typical soft lens appearance with long drying time 4 Excellent: Appearance of a healthy cornea with very long drying time)
Time frame: 2-weeks
Lens surface wettability was measured on a scale of 0-4, 0.25 steps (0 Very Poor: Immediately displaying non-wetting areas on the lens surface, immediate drying time, 1 Poor: Irregular surface appearance, drying time << blink time, 2 Acceptable: Smooth surface appearance immediately, after the blink becoming irregular after a while, drying time ≤ blink time, 3 Good: Typical soft lens appearance with long drying time 4 Excellent: Appearance of a healthy cornea with very long drying time)
Time frame: 4-weeks
Lens surface wettability was measured on a scale of 0-4, 0.25 steps (0 Very Poor: Immediately displaying non-wetting areas on the lens surface, immediate drying time, 1 Poor: Irregular surface appearance, drying time << blink time, 2 Acceptable: Smooth surface appearance immediately, after the blink becoming irregular after a while, drying time ≤ blink time, 3 Good: Typical soft lens appearance with long drying time 4 Excellent: Appearance of a healthy cornea with very long drying time)
Time frame: Baseline
Lens surface deposits was measured on a Scale 0-4, 0.25 steps (0: Clean, no deposits, 1: 5 or less small deposits (<0.1mm), 2: >5 deposits of <0.1mm size or film covering 25-50% of surface, 3: Deposits of between 0.1 and 0.5mm or film covering 50-75% of surface, 4: Deposits of 0.5mm or larger or film covering more than 75% of surface)
Time frame: 2-weeks
Lens surface deposits was measured on a Scale 0-4, 0.25 steps (0: Clean, no deposits,1: 5 or less small deposits (<0.1mm), 2: >5 deposits of <0.1mm size or film covering 25-50% of surface, 3: Deposits of between 0.1 and 0.5mm or film covering 50-75% of surface, 4: Deposits of 0.5mm or larger or film covering more than 75% of surface).
Time frame: 4-weeks
Lens surface deposits was measured on a Scale 0-4, 0.25 steps (0: Clean, no deposits,1: 5 or less small deposits (<0.1mm), 2: >5 deposits of <0.1mm size or film covering 25-50% of surface, 3: Deposits of between 0.1 and 0.5mm or film covering 50-75% of surface, 4: Deposits of 0.5mm or larger or film covering more than 75% of surface)
Time frame: Baseline
Overall lens fit acceptance was measured on a scale of 0-4, 0.25 steps (0 Unacceptable-Can't be worn, 1 Acceptable -Poor/worn under supervision, 2 Acceptable -Fair, prefer refit, 3 Acceptable -Good, 4-Acceptable -Optimum)
Time frame: 2-Weeks
Overall lens fit acceptance was measured on a scale of 0-4, 0.25 steps (0 Unacceptable-Can't be worn, 1 Acceptable -Poor/worn under supervision, 2 Acceptable -Fair, prefer refit, 3 Acceptable -Good, 4-Acceptable -Optimum)
Time frame: 4-Weeks
Overall lens fit acceptance was measured on a scale of 0-4, 0.25 steps (0 Unacceptable-Can't be worn, 1 Acceptable -Poor/worn under supervision, 2 Acceptable -Fair, prefer refit, 3 Acceptable -Good, 4-Acceptable -Optimum)
Time frame: Baseline
Lens Centration was assessed in primary gaze, white light, diffuse, 8xmag, with graticule on a grade of Optimum, Slightly decentered (<0.5mm), Extremely decentered (>0.5mm)
Time frame: 2-weeks
Lens Centration was assessed in primary gaze, white light, diffuse, 8xmag, with graticule on a grade of Optimum, Slightly decentered (<0.5mm), Extremely decentered (>0.5mm)
Time frame: 4-weeks
Lens Centration was assessed in primary gaze, white light, diffuse, 8xmag, with graticule on a grade of Optimum, Slightly decentered (<0.5mm), Extremely decentered (>0.5mm)
Time frame: Baseline
Bulbar Conjunctiva Hyperaemia was measured on a scale of 0-4, 0.25 steps (0=None, 4=Severe injection)
Time frame: 2-weeks
Bulbar Conjunctiva Hyperaemia was measured on a scale of 0-4, 0.25 steps (0=None, 4=Severe injection)
Time frame: 4-weeks
Bulbar Conjunctiva Hyperaemia was measured on a scale of 0-4, 0.25 steps (0=None, 4=Severe injection)
Time frame: Baseline
Limbal Conjunctiva Hyperaemia was measured on a Scale of 0-4, 0.25 steps (0=None, 4=Severe injection)
Time frame: 2-weeks
Limbal Conjunctiva Hyperaemia was measured on a Scale of 0-4, 0.25 steps (0=None, 4=Severe injection)
Time frame: 4-weeks
Limbal Conjunctiva Hyperaemia was measured on a Scale of 0-4, 0.25 steps (0=None, 4=Severe injection)
CooperVision, Inc.
Industry
A Dispensing Clinical Trial of Invigor I Lens Against Clariti Lens
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT03334253
Eye Diseases, Myopia
Birmingham, Alabama, United States
View Trial DetailsNCT07087665
Eye Diseases, Myopia
Saint Louis Park, Minnesota, United States
View Trial DetailsNCT06700460
Eye Diseases, Myopia
Omaha, Nebraska, United States
View Trial DetailsNCT00320593
Eye Diseases, Myopia
Birmingham, Alabama, United States
View Trial Details