Division of Cardiology, Department of Internal Medicine, Yonsei University College of Medicine
Seoul, 120-752, South Korea
NCT Number: NCT02466282
It is well-known that non-optimal stent implantation associated with under-expansion or incomplete strut apposition during percutaneous coronary intervention (PCI) leads to a higher incidence of restenosis and stent thrombosis. OCT-guided PCI with metallic stent has previously been shown to be safe and feasible, resulting in better clinical outcomes compared with angiography-only guided PCI. Everolimus-eluting bioabsorbable vascular scaffold (BVS; Abbott Vascular, Santa Clara, CA, USA) was made from a bioabsorbable polylactic acid backbone which is coated with a more rapidly absorbed polylactic acid layer that contains and controls the release of the antiproliferative drug, everolimus. BVS has a number of proposed advantages over current metallic stent technology. These include elimination of chronic sources of vessel irritation and inflammation, which can reduce the potential risk of late scaffold thrombosis after complete scaffold bioresorption. Although the current generation of the Absorb BVS have larger strut thickness of 150 μm compared with 80 μm of strut of Xience stent, the acute recoil of the polymeric device was similar to that of metallic stent. However, operators tented to use dilating devices less aggressively because of the concerns about limitation in elongation-at-break of polylactide. Previous studies reported 20-30% of under-expansion or malapposition with BVS, which would increase the risk of adverse events including late stent thrombosis. OCT-guidance may improve more optimized scaffold placement and also better outcomes. Therefore, investigators will compare OCT guidance and angiography-only guidance for PCI with BVS regarding incomplete scaffold apposition and neointimal scaffold coverage. Investigators are also going to compare these two strategies regarding clinical outcomes with verification of the cut-off value by OCT-acquired uncovered scaffold rate.
Looking for future studies?
Notify Me19 year and older
All sexes
Interventional
Not applicable
Seoul, 120-752, South Korea
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Everolimus-eluting bioresorbable vascular scaffold (Absorb, Abbott Vascular, Santa Clara, CA, USA) was made from a bioabsorbable polylactic acid backbone which is coated with a more rapidly absorbed polylactic acid layer that contains and controls the release of the antiproliferative drug, everolimus. PCI will be performed with BVS under conventional coronary angiography without any other intravascular imaging modality.
Everolimus-eluting bioresorbable vascular scaffold (Absorb, Abbott Vascular, Santa Clara, CA, USA) was made from a bioabsorbable polylactic acid backbone which is coated with a more rapidly absorbed polylactic acid layer that contains and controls the release of the antiproliferative drug, everolimus. For optimized PCI, both conventional coronary angiography and optical coherence tomography can be used before and after stent implantation. OCT study should be checked at the final post-procedure and stent implantation is optimized.
Time frame: six months
Percentage of uncovered scaffold struts between OCT guidance vs. angiography-only guidance PCI on 6 month OCT
Time frame: until one year
Cardiac death, myocardial infarction, target vessel revascularization, stent thrombosis, cerebrovascular accident and major bleeding between OCT guidance vs. angiography-only guidance PCI until 12 months
*Major bleeding ; causing mortality, hypovolemic shock or severe hypotension requiring inotropes or surgery, intrapericardial with tamponade, significant disabling (e.g. intraocular bleeding leading to loss of vision), symptomatic intracranial haemorrhage, intraocular bleeding leading to loss of vision, hemoglobin drop ≥ 3g/dL, or requiring transfusion more than 2 units
Time frame: six months after stent implantation
Scaffold strut malapposition: Malapposition is defined by a clear seperation between the abluminal side of the strut and the vessel wall. As a result, scaffold malapposition is defined as the presence of any malapposed struts. percentage of malapposed struts (% malapposed strut) was the ratio of malapposed struts from total analyzable struts.
Yonsei University
Other
A Randomized Controlled Comparison of Optical Coherence Tomography Guidance and Angiography-only Guidance for Percutaneous Coronary Intervention With Bioresorbable Vascular Scaffold
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT03188705
Arterial Occlusive Diseases, Arteriosclerosis
Lancaster, Pennsylvania, United States
View Trial DetailsNCT07468955
Arterial Occlusive Diseases, Arteriosclerosis
Kütahya, Center, Turkey (Türkiye)
View Trial DetailsNCT06029517
Arterial Occlusive Diseases, Arteriosclerosis
Buffalo, New York, United States
View Trial DetailsNCT04058990
Arterial Occlusive Diseases, Arteriosclerosis
Kitakyushu, Fukuoka, Japan
View Trial Details