Department of clinical science and education, Södersjukhuset
Stockholm, 11883, Sweden
NCT Number: NCT01442298
The use of bloodless field is a helpful and important method in orthopedic surgery. The surgery can be done without interrupting bleedings, while keeping an exact overlook of the anatomy. However the method is not without risks, and complications of various kind may occur. One of the most important factors to minimise the risk of complications, is to keep the lowest possible cuff pressure. Previous electromyography (EMG) studies have indicated neuromuscular abnormalities after bloodless field among many patients which may lead to a prolonged rehabilitation period since they cause a postoperative weakness in the muscles. Although in these studies an unnecessary high tourniquet pressures were used and the EMG tests were made 6 weeks and 6 months after the surgery.
With today's demand for fast rehabilitation, there is a need for better knowledge if lower tourniquet pressure in bloodless field surgery may lead to less neuromuscular abnormalities.
Limb Occlusion Pressure (LOP) is the tourniquet cuff pressure required to occlude the blood flow. It accounts for a patients limb and vessel characteristics and the type and fit of the tourniquet cuff. The method has developed and is now simplified, by using an automatic (plethysmographic) sensor placed on the second toe on the involved limb, and after administration of anaesthesia, and immediately before limb preparation and draping it measures the limb occlusion pressure.
When surgery starts, the cuff is inflated again; plus a safety margin based on the LOP pressure measured. The LOP method is still rarely used it has been seen as difficult and time consuming.
The primary aim of this study is to investigate whether you can reduce the used tourniquet pressure with the new LOP measurement technique and still have a adequate bloodless field; and if this will lead to any clinical difference regarding postoperative pain. The secondary aim is to investigate the difference between the test groups concerning muscle function and wound healing and if these are remaining and of clinical importance. The third aim is to study how common neuromuscular abnormalities are after the use of bloodless field with lower cuff pressures and if there are any differences between the standard method and the LOP method.
Looking for future studies?
Notify MeUp to 75 year
All sexes
Interventional
Not applicable
Stockholm, 11883, Sweden
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
The tourniquet cuff pressure were decided by measurement of limb occlusion pressure (LOP) using an automated photo plethysmographic sensor connected to a ATS 3000 tourniquet apparatus (Zimmer Sweden Inc®).
Standard method at our department, the tourniquet cuff pressure was based on the patient's systolic blood pressure and a margin that were decided by the surgeon.
Time frame: participantswill be followed for the duration of hospital stay , an expected avarage of 4-5 days
For patients in the control group the tourniquet cuff pressure was based on the patient's systolic blood pressure and a margin that were decided by the surgeon. In the LOP group the tourniquet cuff pressure were decided by measurement of limb occlusion pressure (LOP) by using an automated photo plethysmographic sensor connected to a ATS 3000 tourniquet apparatus
Time frame: particpants will be followed for the duration of the hospital stay, an expected avarage of 4-5 days
Direct after surgery the surgeon rated the quality of bloodless fiels on a visual analog scale (VAS)
Time frame: The participants were followed daily during their hospital stay (4-5 days) and at the two months follow up after surgery
The patients filled in the modified WOMAC scale daily during their hospital stay. The WOMAC is a self -administered and validated health status instrument with 3 domains i.e. pain , physical function and stiffness.A wound control was performed by a ward nurse at discharged. The functional assessment included measurement of the range of motion of the knee joint and a straight leg lifting test (with 1kg weigth) and was performed at third postoperative day by an independent physiotherapist. All patients were followed up two months postoperatively (wound, ROM and WOMAC).
Time frame: The participants were examined at third postoperative day and at the two months follow up after surgery
Time frame: The participants were examined at discharged (day 4 or 5 postoperatively) and at the two months follow up after surgery
Time frame: Participans were examined day three and two months postoperatively
Charlotta Olivecrona
Other
A Comparison Between an Individual Low Tourniquet Pressure Versus a Standard Pressure During Total Knee Arthroplasty. A Randomized Controlled Study
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT01820611
Arthritis, Arthritis, Rheumatoid
Turku, Finland
View Trial DetailsNCT01882751
Complications; Arthroplasty
Knoxville, Tennessee, United States
View Trial DetailsNCT01373099
Arthritis, Complications; Arthroplasty
Chicago, Illinois, United States
View Trial DetailsNCT01373112
Arthritis, Complications; Arthroplasty
Chicago, Illinois, United States
View Trial Details