Skip to main content
OpenTrials
Not Yet Recruiting

NCT Number: NCT07399340

A Comparative Evaluation of the Role of Self-Adhesive Flowable Composite in Enhancing Sealant Retention Versus Conventional Pits and Fissure Sealant With and Without Fissurotomy in Permanent Molars

This RCT study aims to establish evidence-based decision comparing between self-adhering flowable composite Vertise™ Flow (Kerr, Orange, CA, USA) and conventional resin-based pits & fissure sealant Helioseal-F sealant (Ivoclar Vivadent AG, Schaan, Liechtenstein) with and without fissurotomy in sealant retention and prevention of occlusal pits and fissures caries in first permanent molars over a 12-month follow-up.

Not Yet Recruiting

Trial opening soon.

Get Notified

Key information

Age range

6 year–8 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Faculty of Dentistry, Cairo University, Cairo, State/Province *, Egypt

Loading trial locations.

About this study

This randomized controlled clinical trial aims to compare the retention and clinical performance of a self-adhering flowable composite and a conventional resin-based pit and fissure sealant, applied with and without fissurotomy, in newly erupted permanent first molars of children aged 6-8 years.

Occlusal pits and fissures are highly susceptible to dental caries in children, and long-term sealant effectiveness is strongly dependent on material retention and technique sensitivity. Self-adhering flowable composites offer simplified application with fewer clinical steps and may improve retention, especially in pediatric patients.

Eighty-eight children will be randomly allocated into four parallel groups (1:1:1:1): self-adhering flowable composite with fissurotomy, self-adhering flowable composite without fissurotomy, conventional resin-based sealant with fissurotomy, and conventional resin-based sealant without fissurotomy.

Sealant retention will be assessed as the primary outcome using Simonsen's criteria, while secondary outcomes include caries development, marginal discoloration, and marginal integrity evaluated using Ryge criteria.

Clinical evaluations will be performed at baseline, 3, 6, and 12 months.

The findings of this study aim to provide evidence-based guidance on the optimal material and technique for pit and fissure sealing in children, potentially improving sealant longevity, reducing occlusal caries incidence, and enhancing preventive pediatric dental care.

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Normal healthy children aged 6 to 8 years.
  • Children with high caries risk
  • Completely erupted lower first permanent molars with deep pits and fissures.
  • Fissures either intact, sound or retentive which are stained, caries free or ICDAS 0-2.
  • Availability for the duration of the study.
  • Satisfactory dental care performed at home.

Exclusion criteria

  • Children whose parents refuse to sign informed consent.
  • Long-term medication affecting the salivary flow.
  • Children enrolled for other studies or fluoridation program.
  • Adverse reaction reported to any dental material.
  • Uncooperative child.
  • Bruxism or malocclusion.
  • Children with developmental defects/ hypoplastic molars or caries affected teeth (ICDAS>2).
  • Teeth with restoration and partially retained sealants.
  • Children who cannot come for the follow-up.

Treatment and study plan

Self adhering flowable composite Vertise™ Flow (Kerr, Orange, CA, USA) with fissurotomy.

Other
  • Pits and fissures will be prepared using a Micro STF fissurotomy bur (SS White Burs Inc., Lakewood, NJ, USA) on a high-speed hand piece, the bur will be moved along all the occlusal fissures with a gentle force applied. (Bagherian et al., 2013)
  • Then washing and drying the tooth with compressed air.
  • Then self-adhering flowable composite (Vertise Flow, Kerr, Orange, CA, USA) with an A2 shade will be applied on occlusal fissures in 0.5mm and brushed on preparation for 15-20sec using a micro-brush with moderate pressure. (Sabbagh et al., 2017; Sharma et al., 2018)
  • Excess material around the margins will be removed.
  • After ensuring that there are no bubbles, the sealant will be cured for 20 seconds by light cure. (Woodpecker RTA Mini S, China).
  • If necessary, another layer will be applied and cured for 20 seconds.

Self adhering flowable composite Vertise™ Flow (Kerr, Orange, CA, USA) without fissurotomy.

Other
  • Before applying Vertise Flow, surface pretreatment according to the manufacturers' recommendations for uncut enamel.(Kucukyilmaz and Savas, 2015) Using 37.5 % phosphoric acid gel Ivoclar Vivadent AG, Schaan, Liechtenstein) for 30-60 seconds according to the manufacturer's instructions, rinsed for 60 seconds and air-dried with oil- and water-free air spray using clean compressed air until observing the chalky white appearance.
  • Then self-adhering flowable composite (Vertise Flow, Kerr, Orange, CA, USA) with an A2 shade will be applied in 0.5mm and brushed on fissures for 15-20sec using a micro-brush with moderate pressure.(Sabbagh et al., 2017; Sharma et al., 2018)
  • Remove excess material around the margins.
  • After ensuring that there are no bubbles, the sealant will be cured for 20 seconds by light cure. (Woodpecker RTA Mini S, China).
  • If necessary, another layer will be applied and cured for 20 seconds.

Conventional resin-based pits and fissure sealant Helioseal-F with fissurotomy.

Other
  • Pits and fissures will be prepared using a Micro STF fissurotomy bur (SS White Burs Inc., Lakewood, NJ, USA) on a high-speed hand piece, the bur will be moved along all the occlusal fissures with a gentle force applied. (Bagherian et al., 2013)
  • Then the occlusal surface of the teeth will be dried and etched with 37% phosphoric acid (Ivoclar Vivadent AG, Schaan, Liechtenstein) for 15-30 seconds according to the manufacturer's instructions, rinsed for 30 seconds and air-dried with oil- and water-free air spray using clean compressed air until observing the chalky white appearance.
  • Helioseal-F sealant (Ivoclar Vivadent AG, Schaan, Liechtenstein) will be applied and directed into the pits and fissures by a sterile explorer to check that there are no air bubbles and light cured for 40 seconds by light cure. (Woodpecker RTA Mini S, China).

Conventional resin-based pits and fissure sealant Helioseal-F without fissurotomy.

Other
  • The occlusal surface of the teeth will be dried and etched with 37% phosphoric acid (Ivoclar Vivadent AG, Schaan, Liechtenstein) for 30-60 seconds according to the manufacturer's instructions, rinsed for 30 seconds and air-dried with oil- and water-free air spray using clean compressed air until observing the chalky white appearance.
  • Helioseal-F sealant (Ivoclar Vivadent AG, Schaan, Liechtenstein) will be applied and directed into the pits and fissures by a sterile explorer to check that there are no air bubbles and light cured for 40 seconds by light cure. (Woodpecker RTA Mini S, China )

Primary outcomes

  1. Sealant retention

    Time frame: 3,6,12 months

    Simonsen's criteria Score 1: Complete retention Score 2: Partial loss Score 3: Complete loss

Secondary outcomes

  1. Presence of Caries

    Time frame: 3,6,12 months

    Ryge criteria Alpha: Absence of caries Bravo: Prescence of caries

  2. Marginal discoloration

    Time frame: 3,6,12 months

    Ryge criteria Alpha: No discoloration anywhere on the margin around the sealant. Bravo: Visible partial discoloration on the margin around sealant. Charlie: Visible discoloration on the margin around all sealant.

  3. Marginal Integrity

    Time frame: 3,6,12 months

    Ryge criteria Alpha: Sealant had full adaptation to the adjacent tooth structure. Bravo: Evidence of gap detected by the tip of an explorer.

Study contacts

Contact information is provided by the study sponsor or research team.

Eman MM Ramadan, Bachelors'

CONTACT

[email protected]

+201121592653

Sponsors and collaborators

Lead sponsor

Cairo University

Other

Collaborators

  • National Research Centre, Egypt

Registry information

Official study title

A Comparative Evaluation of the Role of Self-Adhesive Flowable Composite in Enhancing Sealant Retention Versus Conventional Pits and Fissure Sealant With and Without Fissurotomy in Permanent Molars: A Randomized Controlled Trial

Important dates

Study start
2026
Primary completion
2026
Study completion
2027
First posted
Feb 10, 2026
Registry last updated
Feb 10, 2026

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.