HeartWare® VAS (HVAD)
DeviceThe HeartWare® VAS is an implantable centrifugal pump that was designed to provide flows up to 10 L/min in a small device that is both lightweight and simple to use.
NCT Number: NCT01966458
This is a prospective, randomized, controlled, unblinded, multi-center evaluation of safety and efficacy in patients implanted with a HeartWare® HVAD who receive improved blood pressure management. Subjects have chronic Stage D or NYHA Class IIIB/IV left ventricular failure who have received and failed optimal medical therapy, and who are ineligible for cardiac transplantation.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
The University of Alabama at Birmingham, Birmingham, Alabama, United States
The study will evaluate non-inferiority of neurologic injury incidence in a new cohort of subjects receiving improved blood pressure management to a control group (i.e., any FDA-approved LVAD for destination therapy). Secondary endpoints include: a comparison of stroke/TIA incidence to a reference observed in the original IDE clinical trial (HW004) that did not specify improved blood pressure management; and non-inferiority of stroke-free success on the originally implanted device to the control group. Subjects will be randomized to HeartWare® HVAD or control LVAD in a 2:1 ratio. Each subject receiving the HeartWare® HVAD or control LVAD is followed to the primary and secondary endpoints at 12 months, with a subsequent follow-up period extending to 60 months post-implant.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
The HeartWare® VAS is an implantable centrifugal pump that was designed to provide flows up to 10 L/min in a small device that is both lightweight and simple to use.
Any FDA-approved LVAD for destination therapy.
Time frame: Implant to 12 Months
The primary endpoint is the percent of participants at 12 months on the originally implanted device with neurologic injury, defined as a stroke with Modified Rankin Scale (MRS) > 0 at 24-weeks post-stroke, or a transient ischemic attack (TIA), or a spinal cord infarction (SCI). The Modified Rankin Scale is scored from 0 to 6, where 0 indicates an absence of symptoms and 6 indicates death. A score of 4 or higher indicates moderately severe or greater disability.
Time frame: Implant to 12 Months
The first secondary endpoint is the number of HeartWare VAS participants with stroke/TIA at 12 months on the originally implanted device.
Time frame: Implant to 12 Months
Success is defined as alive on the originally implanted device, electively transplanted or explanted due to subject recovery and free from disabling stroke (Modified Rankin Scale >=4).
Medtronic Cardiac Rhythm and Heart Failure
Industry
A Prospective, Randomized, Controlled, Unblinded, Multi-Center Clinical Trial to Evaluate the HeartWare™ Ventricular Assist Device System for Destination Therapy of Advanced Heart Failure
Acronym: DT2
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07697365
Cardiovascular Diseases, Chronic Heart Failure
Athens, Attica, Greece
View Trial DetailsNCT07599345
Chronic Heart Failure, Heart Failure With Reduced Ejection Fraction
Boston, Massachusetts, United States
View Trial DetailsNCT07599293
Chronic Heart Failure, Diabetes Mellitus
Boston, Massachusetts, United States
View Trial DetailsNCT06299826
Chronic Heart Failure
Alexander City, Alabama, United States
View Trial Details