Sunshine Eye Surgeons
Melbourne, Victoria, 3021, Australia
Location status: Recruiting
NCT Number: NCT07059754
The goal of this clinical trial is to understand what effect a cold treatment with an investigational device, ETX-4143, has on the anatomical structures and the inflammatory response of the surface of the eye in those people who suffer from chronic ocular surface pain (COSP). The trial will also tell us more about the safety of this investigational device. The main questions this study aims to answer are:
* What anatomical changes happen to corneal surface nerves after treatment with ETX-4143 * What changes in inflammatory mediators and cell response take place after treatment with ETX-4143
Researchers will obtain images of the corneal surface nerves for analysis using a confocal microscope and collect tear bio samples for analysis.
Participants will:
* Be screened for having chronic ocular surface pain * Will be treated with ETX-4143 cold treatment for 4 minutes * Fill out a weekly questionnaire on eye pain for 12 weeks * Be seen in the clinic 2 weeks, 6 weeks, and 12 weeks after treatment to have images of the corneal surface taken, and to collect a tear bio sample
Interested in participating?
Request Info22 year–90 year
All sexes
Interventional
Not applicable
Melbourne, Victoria, 3021, Australia
Location status: Recruiting
EyeCool Therapeutics was founded on the hypothesis that a mild ocular surface cooling treatment, delivered through its proprietary cooling device (ETX-4143), can improve the symptoms of chronic ocular surface pain by transiently inhibiting nerve signaling, and potentially reducing ocular surface inflammation, and potentially restoring normal ocular surface nerve function.
The ETX-4143 Device is a handheld medical device that contains an internal frozen (-20° Centigrade) mixture of purified water and glycerol. The ETX-4143 Device does not contain an active pharmaceutical ingredient. The frozen mixture internally cools two metallic probes that contact the conjunctival surface of the patient; there is no direct contact of the ocular surface with the frozen mixture. Prior to placement of the device on the ocular surface, local anesthesia is administered and a custom speculum used to open and insulate the eyelids, as well as promote correct positioning of the Device. A cornea shield is applied to maintain corneal wetness during the procedure. The Device and accessory (speculum) are provided in disposable, single-use packaging.
In this prospective, single-center, single-center clinical study, 5 adult subjects with chronic ocular surface pain will be identified and treated with the ETX-4143 Device (Cooling Device for topical ophthalmic use). The main goal of the study is to further evaluate the device for changes in ocular surface components using in vivo confocal microscopy, and for safety and efficacy. Improvement in self-reported ocular discomfort and clinical safety measures will be evaluated, along with in vivo confocal microscopy of the cornea before and after treatment.
It is anticipated that the learnings from these observations will be used to design future studies of the ETX-4143 device. In this study, five subjects will receive the investigational product (ETX-4143 Device).
The Medical Monitor will evaluate the clinical safety data as it becomes available and no less than on at least a quarterly basis.
All subjects will be followed for a total of 12 weeks. Subjects will have only the worse eye treated, if both eyes meet the inclusion/exclusion criteria. The worse eye will be determined by the investigator based on subjective reporting from the study subject of chronic ocular surface pain and/or other screening assessments in each eye. Both eyes will be assessed for tear osmolarity and imaged using corneal in vivo confocal microscopy at the University of Melbourne, with the untreated eye representing a control.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Targeted topical ophthalmic cooling treatment using the ETX-4143 cooling device
Time frame: From treatment to the end of twelve weeks
Non-invasive imaging of the corneal surface for assessing ocular tissue structure.
Contact information is provided by the study sponsor or research team.
Cristos Ifantides A Prospective, Feasibility, Single-Center, Clinical Study to E
CONTACT
Patrick Casey, Optometrist
CONTACT
EyeCool Therapeutics, Inc.
Industry
A Prospective, Feasibility, Single-Center, Clinical Study to Evaluate the Effect of the ETX-4143 Topical Ophthalmic Cooling Device on Ocular Surface Structures and Cell Population in Patients With Chronic Ocular Surface Pain
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05931250
Brain Diseases, Brain Injuries
Linköping, Other / Non-US, Sweden
View Trial DetailsNCT05531643
Dry Eye Syndromes, Eye Diseases
Miami, Florida, United States
View Trial DetailsNCT06479382
Eye Diseases, Eye Manifestations
Westmead, New South Wales, Australia
View Trial DetailsNCT05832996
CYSTOID MACULAR EDEMA, Central Retinal Vein Occlusion With Macular Edema
Iowa City, Iowa, United States
View Trial Details