This is a prospective, single-center, observational pilot study of the investigational NIRSense Tissue Oximetry Sensor System (Envello Core), a noninvasive wearable sensor patch that uses near-infrared spectroscopy (NIRS) and photoplethysmography (PPG), combined with an electrocardiography/impedance cardiography (ECG/ICG) sensor, to continuously monitor tissue oxygen saturation (StO2), peripheral oxygen saturation (SpO2), pulse rate, respiratory rate, stroke volume, and related metrics. Up to 20 adults admitted to the Cleveland Clinic Florida cardiac intensive care unit with acute myocardial infarction or acute decompensated heart failure and in Society for Cardiovascular Angiography and Interventions (SCAI) shock stage B, C, or D will wear the sensors on the sternum, forearm, and other locations for approximately 24 to 72 hours during standard care. Sensor data will be compared with standard-of-care hemodynamic and laboratory measurements and with the patient's clinical course to evaluate the feasibility of the device, the correlation of its measurements with established clinical parameters, and its potential to detect deterioration in SCAI shock stage earlier. No treatment decisions are made based on the study device.
Interested in participating?
Request Info18 year and older
All sexes
Observational
Weston, Florida, 33331, United States
Location status: Recruiting
David A. Baran, MD
CONTACT
David A. Baran, MD
PRINCIPAL_INVESTIGATOR
Maxwell Sapper
CONTACT
Background: Cardiogenic shock (CS) carries a poor prognosis and is the leading cause of death in patients with acute myocardial infarction. When decompensation occurs there is an imperative to institute treatment rapidly. Standard intensive care unit monitoring relies on intermittent hemodynamic and laboratory measures. Continuous, noninvasive measurement of tissue perfusion and oxygenation could allow earlier recognition of deterioration and earlier intervention.
Device: The NIRSense Tissue Oximetry Sensor System is an investigational, non-significant-risk, noninvasive wearable optical physiological monitoring system. It consists of a sensor patch with multiple red and near-infrared light sources and detectors (NIRS and PPG), a pre-applied medical-grade adhesive, an ECG/ICG sensor patch, and a display unit (tablet running the NIRSense application) that receives data over Bluetooth and stores it. The sensor estimates StO2 in microvascular tissue up to about 2.5 cm below the skin and derives PPG-based metrics including pulse rate, respiratory rate, and perfusion index. The device has not been cleared or approved by the U.S. FDA.
Design: Prospective data collection, single-center observational study. Two populations are targeted: (1) patients with acute myocardial infarction, with or without shock (SCAI B to D), admitted for coronary angiography and subsequent interventions, and (2) patients with acute decompensated heart failure admitted for pulmonary artery catheter insertion and subsequent interventions. Participants are enrolled from the existing Cleveland Clinic Florida patient population in a way that avoids disruption of clinical workflow. After informed consent, sensors are placed on the sternum, forearm, and other locations according to manufacturer specifications and remain in place while the patient is in the cardiac intensive care unit, for approximately 24 to 72 hours. Sensors may be repositioned during catheterization or imaging at the investigator's discretion. Participation is limited to the single standard-of-care admission; there is no study follow-up visit or call.
Data collected: Continuous sensor data (StO2, SpO2, pulse rate, respiratory rate, ECG/ICG-derived stroke volume, PPG-derived metrics) and sensor placement images. Data collected during standard-of-care treatment and shared with the sponsor: demographics, Fitzpatrick skin type, medical history, concomitant medications, physical examination, vital signs, a single 12-lead ECG, blood pressure, heart rate, cardiac output (thermodilution) where obtained, clinically ordered lactate values, SCAI stage, and clinical course. Adverse events and device deficiencies are recorded from enrollment through sensor removal. Clinical staff complete a usability survey after using the device on 5 patients.
Analysis: Descriptive statistics for demographics and baseline characteristics; adverse events summarized by frequency and percentage, severity, and device relatedness. Effectiveness analyses use all evaluable data and compare device measurements with standard-of-care hemodynamic parameters and with SCAI stage trajectory, as specified in the Statistical Analysis Plan. Following an interim analysis of the 20-patient pilot, enrollment may be expanded to 200 patients under a protocol amendment; that expansion is not part of this record.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Investigational noninvasive wearable sensor patches using near-infrared spectroscopy and photoplethysmography to continuously measure tissue oxygen saturation, SpO2, pulse rate, respiratory rate, and perfusion index, plus an ECG/ICG sensor patch for stroke volume, with a tablet display and recording application. Sensors are applied to the sternum, forearm, and other locations with a medical-grade adhesive and worn for approximately 24 to 72 hours during standard cardiac ICU care. Sensor data are collected for research only and are not used for treatment decisions.
Other names: Envello Core, NIRSense Sensor Oximetry System patch
Time frame: Continuous monitoring during the cardiac ICU stay, approximately 24 to 72 hours from sensor application
Correlation coefficients (Pearson and Spearman) between time-matched NIRSense measurements (tissue oxygen saturation, perfusion index, SpO2, pulse rate, respiratory rate, ICG-derived stroke volume) and standard-of-care clinical measurements (arterial blood pressure, heart rate, pulmonary artery and central venous pressures where a pulmonary artery catheter is present, cardiac output by thermodilution, and lactate).
Time frame: Continuous monitoring during the cardiac ICU stay, approximately 24 to 72 hours from sensor application
Percentage of the intended monitoring period during which each sensor provided valid StO2 and PPG data, per sensor site, including data recovered from onboard memory after wireless transmission gaps.
Time frame: From enrollment through sensor removal, approximately 24 to 72 hours
Number and percentage of participants with adverse events, adverse device effects (including skin irritation or redness at the adhesive site), and device deficiencies, and number of participants requesting early sensor removal.
Time frame: Continuous monitoring during the cardiac ICU stay, approximately 24 to 72 hours from sensor application
Change in NIRSense measurements (StO2, StO2 variability, perfusion index, stroke volume) relative to the time of clinically documented change in SCAI shock stage, including the lead time between the first sustained change in device metrics and the clinically recognized deterioration.
Time frame: Continuous monitoring during the cardiac ICU stay, approximately 24 to 72 hours from sensor application
Summary statistics of StO2, perfusion index, and ICG-derived stroke volume at each sensor site by SCAI shock stage (B, C, D, E), to inform development of a predictive model of shock status.
Time frame: After the device has been used on 5 patients (approximately 1 to 6 months after first enrollment)
Responses to a paper survey completed by study staff (principal investigator, nurses, residents, and others involved in the study) on their experience using the sensor system.
Contact information is provided by the study sponsor or research team.
NIRSense Inc.
Industry
Clinical Evaluation of Using NIRSense Sensor Patch to Measure Microvascular Perfusion Responses and Predict Decompensation in Cardiogenic Shock Patients
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06081205
Acute Decompensated Heart Failure, Acute Myocardial Infarction
Ioannina, Epirus, Greece
View Trial DetailsNCT07643610
Acute Decompensated Heart Failure, Cardiogenic Shock
Basel, Canton of Basel-City, Switzerland
View Trial DetailsNCT05185492
Acute Myocardial Infarction, Cardiogenic Shock
Weston, Florida, United States
View Trial DetailsNCT04184635
Acute Myocardial Infarction, Cardiogenic Shock
Paris, France
View Trial Details