University of Wisconsin
Madison, Wisconsin, 53792, United States
NCT Number: NCT07747662
This research sub-study is to evaluate if combining images from Optical Coherence Tomography (OCT) scans with Adaptive Optics Scanning Light Ophthalmoscopy (AOSLO) and Microperimetry (MP) could show a link between structural changes in the back of the eye and vision. 10 participants that were enrolled in the COmparison of Clarus and Optos Ultrawide Field Imaging Systems for Geographic Atrophy study [NCT05961332] will be approached to enroll. Participants may complete OCT imaging and initial assessments during an initial visit and may return for additional procedures, including microperimetry and AOSLO imaging, within a window of up to 4 weeks.
Interested in participating?
Request Info50 year and older
All sexes
Interventional
Not applicable
Madison, Wisconsin, 53792, United States
Age-related macular degeneration (AMD) is a leading cause of blindness worldwide, with geographic atrophy (GA) representing the advanced, untreatable form of the disease. GA leads to progressive degeneration of retinal cells critical for vision, resulting in irreversible vision loss and a significant impact on patients' quality of life. Despite the prevalence of GA, treatment options remain limited. Current therapeutic strategies focus on slowing the enlargement of atrophic regions, but clinical trials have faced challenges in demonstrating clear patient benefits.
In clinical practice, GA progression is often evaluated by measuring the area of atrophy on retinal imaging, such as fundus autofluorescence (FAF) and, more recently, optical coherence tomography (OCT). These structural biomarkers are used in clinical trials to assess the efficacy of new drugs, with the FDA accepting a reduction in the rate of GA enlargement as a successful outcome. However, these structural metrics often fail to correlate with functional vision loss, leaving patients and physicians disappointed by treatments that may stabilize GA progression without improving their visual outcomes.
The ellipsoid zone (EZ), a hyperreflective layer visualized on OCT, represents the structural integrity of photoreceptors-cells responsible for converting light into visual signals. In patients with one or more GA lesions, OCT imaging shows that the EZ is typically absent within the GA, while the EZ in the perilesional zone may be attenuated or damaged. Perilesional EZ loss is thought to represent the area at highest risk for future vision loss. With the FDA approval of photoreceptor preservation as an endpoint for GA trials, there has been significant interest in measuring EZ loss from OCT scans. Drug approval will now focus on the prevention of EZ loss in the perilesional areas rather than GA area expansion. However, it is important to establish whether the absence of the EZ truly indicates photoreceptor damage and whether there is a functional correlation between EZ loss and visual sensitivity. Adaptive Optics and microperimetry are two modalities that can help address this.
This sub-study is a pilot comparative imaging study. In addition to the imaging procedures collected for the main COCO GA study [NCT05961332], participants will have the following study images obtained:
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
(from the main study):
Additional Sub-study Inclusion Criteria:
Exclusion criteria
(from the main study):
Additional Sub-study Exclusion Criteria:
AOSLO imaging offers unprecedented resolution by correcting optical distortions, enabling direct visualization of individual photoreceptors. The procedure takes 60 minutes.
Other names: AOSLO
Microperimetry measures retinal sensitivity at specific retinal locations while tracking eye movements, enabling precise correlation with structural changes. The procedure takes up to 45 minutes.
OCT will be performed using the Heidelberg Spectralis system with a high-resolution scanning protocol. This is a repeat procedure, the first image was obtained in the main study. The procedure takes 5 minutes.
Other names: OCT
Time frame: up to 6 hours total during one or two study visits
The aim is to validate the use of AOSLO imaging for OCT-based EZ classifications, directly visualizing photoreceptor mosaics and correlating EZ loss with photoreceptor structure.
Semi-automated machine learning algorithms will be used to segment the EZ layer on OCT images and generate en face maps. All algorithm outputs will be reviewed and verified by trained human graders.
AOSLO imaging will validate these maps by providing photoreceptor cell counts and qualitative assessments in the same region
Time frame: up to 6 hours total during one or two study visits
The aim is to validate the use of AOSLO imaging for OCT-based EZ classifications, directly visualizing photoreceptor mosaics and correlating EZ loss with photoreceptor structure.
Semi-automated machine learning algorithms will be used to segment the EZ layer on OCT images and generate en face maps. All algorithm outputs will be reviewed and verified by trained human graders.
Graders will independently measure area of EZ loss from images of each device. The measurements (in mm²) will be compared between the two devices.
Time frame: up to 6 hours total during one or two study visits
The aim is to correlate structural metrics (EZ status from OCT and AOSLO) with functional data (microperimetry), establishing EZ loss as a reliable biomarker for vision loss.
University of Wisconsin, Madison
Other
Structure and Function in the Progression of Atrophic AMD: Validation of Photoreceptor Damage Observed With OCT Using AOSLO (Adaptive Optics Scanning Light Ophthalmoscopy and Microperimetry
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07529041
Blindness, Eye Diseases
Göttingen, Germany
View Trial DetailsNCT07807969
Eye Diseases, Geographic Atrophy
Sarasota, Florida, United States
View Trial DetailsNCT07174687
Eye Diseases, Eye Diseases, Hereditary
St Louis, Missouri, United States
View Trial DetailsNCT02479386
Eye Diseases, Geographic Atrophy
Springdale, Arkansas, United States
View Trial Details