The Ottawa Hospital
Ottawa, Ontario, K1H 8L6, Canada
NCT Number: NCT05393778
Accurate reconstruction of the native hip parameters following total hip arthroplasty is associated with improved outcome. In order to improve ability for optimum reconstruction, 3-D templating software can be utilized that provide detailed information regarding native anatomy. In order to achieve reconstruction within acceptable parameters as per pre-operative plan, some surgeons propose the use of intra-operative devices that measure component orientation and joint reconstruction ("Measured-THA"), whilst others propose the use of navigation tools ("Navigation-THA). Both techniques have shown superiority compared to the most commonly used "freehand" technique, but no prior study has assessed for superiority between these 2 techniques. Furthermore, to-date assessment of post-operative reconstruction has not been tested in detail as post-THA assessments are based on radiographs which provide incomplete, 2-dimensional, assessments and are lacking the important axial plane reconstruction parameters. The aims of this prospective, randomized, trial are to 1. appraise the ability to achieve the pre-operative 3-D plan (as per FormusLab) through a comparison of pre-op plan to post-operative reconstruction; 2. compare ability to accurately reconstruct hip following THA between "navigated-" (IntelliJoint®) and "measured-" techniques; and in doing so it will also 3. assess the accuracy of the intra-operative assessments of reconstruction through a comparison of objective (i.e. measured) intra-operative assessments with the post-operative reconstructions achieved.
This study is active but is not currently recruiting participants.
Notify MeAll sexes
Interventional
Not applicable
Ottawa, Ontario, K1H 8L6, Canada
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Manual intra-operative checks and tools are used to aid in component placement during surgery.
IntelliJoint® navigation is an imageless-based navigation system that utilizes a miniature infrared camera and microelectronics to measure hip center of rotation, acetabular inclination and version, leg length, and offset. The device provides accurate real-time data on implant positioning to aid in placement of the components during surgery.
Time frame: once pre-operatively and once one-year post-operatively
The Oxford Hip Score will be given to patients to assess subjective measures of hip pain. Scores for each question from 0 to 4 with 4 being the best outcome. This method, when summed, produces overall scores running from 0 to 48 with 48 being the best outcome
Time frame: once pre-operatively and once one-year post-operatively
the EuroQol (EQ-5D-5L) will be given to patients to assess subjective measures mobility, self-care, usual activities, pain/discomfort and anxiety/depression.
Each dimension in the EQ-5D-5L has five response levels: no problems (Level 1); slight; moderate; severe; and extreme problems (Level 5). The maximum score of 1 indicates the best health state, by contrast with the scores of individual questions, where higher scores indicate more severe or frequent problems.
Time frame: once pre-operatively and once one-year post-operatively
the PROMIS Global-10 will be given to patients to assess subjective measures of physical, mental and social health. It is a 10-item patient-reported questionnaire in which the response options are presented as 5-point (as well as a single 11-point) rating scales. The results of the questions are used to calculate two summary scores: a Global Physical Health Score and a Global Mental Health score. Higher scores indicate worse physical and mental health
Time frame: 90 days post-operatively
Serious adverse events will be monitored. This includes:
Time frame: post-operatively (within one week post-operatively)
A measure (in mm) of how close the planned to actual reconstruction using the aforementioned reconstruction parameters. This will be assessed using:
o Accuracy of femoral version restoration
o Accuracy of achieving femoral offset
o Accuracy of achieving acetabular offset
o Accuracy of achieving total offset
Time frame: Through study completion, an average of 1 year
This outcome will measure what the margin of error is between intra-operatively measured values and those determined from the post-operative CT scan. This will be done using statistical analysis of data for patients in both study arms.
Time frame: Through study completion, an average of 1 year
This outcome measure will assess the accuracy of reconstruction correlate with outcome (adverse events and PROMs). This will be done by analyzing accuracy as depicted by the variables in outcome measure 5, and how these measures of accuracy correlate to patient reported outcome measure scores and rates of adverse events
Time frame: post-operatively (within one week post-operatively)
A measure (in degrees) of how close the planned to actual reconstruction using the aforementioned reconstruction parameters. This will be assessed using:
Acetabular component orientation (Radiographic inclination/anteversion in degrees as per Murray)
● Femoral Component Version in degrees
● Combined version of arthroplasty in degrees
Ottawa Hospital Research Institute
Other
Accuracy in aChieving Optimum reconstrUction: Measured- vs. Navigation- Techniques in Hip Arthroplasty
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05584410
Arthritis, Joint Diseases
Gothenburg, Västra Götaland County, Sweden
View Trial DetailsNCT06870123
Arthritis, Joint Diseases
Martin, Slovakia
View Trial DetailsNCT04754087
Arthritis, Avascular Necrosis of Hip
Denver, Colorado, United States
View Trial DetailsNCT03113981
Arthritis, Bone Diseases
Bordeaux, France
View Trial Details