Skip to main content
OpenTrials
Suspended

NCT Number: NCT04526938

Physician-modified Endovascular Graft for Repair of Complex Thoracoabdominal and Abdominal Aortic Aneurysms

The primary objective of this study is to assess the use of a physician-modified Cook Alpha Thoracic Endovascular Graft in the repair of complex aortic aneurysms and thoracoabdominal aortic aneurysms and aneurysms secondary to aortic dissections in high-risk patients having appropriate anatomy. The primary intent of the study is to assess the safety and preliminary effectiveness of the device. Additionally, the study will assess renal function, radiation exposure, and quality of life.

Why the study stopped: PI left institution
Suspended

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

MedStar Washington Hospital Center

Washington D.C., District of Columbia, 20010, United States

About this study

This study is a prospective, single-center, non-randomized, single-arm study. Each enrolled subject will undergo periodic follow-up evaluations involving physical exams, computed tomography angiography (CTA) of chest, abdomen and pelvis, abdominal duplex ultrasound, creatinine measurement, quality of life questionnaire at specific, protocol-defined intervals for a period of five years following the physician-modified Cook Zenith® Alpha Endovascular Graft implant.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Age ≥ 18 years old
  • Life expectancy > 2 year(s)
  • Patient is considered to be at high risk of morbidity and mortality with open surgical repair
  • A patient may be entered into the study if the patient has at least one of the following:
  • Juxtarenal, suprarenal or a thoracoabdominal aortic aneurysm with a diameter ≥ 5.5 cm or 2 times the normal aortic diameter
  • Aneurysm with a history of growth ≥ 0.5 cm per year
  • Saccular aneurysms deemed at significant risk for rupture based upon physician interpretation
  • Symptomatic juxtarenal, suprarenal or a thoracoabdominal aortic aneurysm
  • Thoracoabdominal aortic aneurysms secondary to aortic dissection meeting above criteria
  • Patient is considered to be at high risk of morbidity and mortality with open surgical repair
  • Iliac or femoral access vessel morphology that is compatible with vascular access techniques, devices or accessories, with or without use of a surgical conduit
  • Nonaneurysmal aortic segment proximal to the aneurysm (neck) with a:
  • Minimum neck length of 20mm
  • Diameter in the range of 21-38mm
  • Angle less than 60° relative to the axis of the aneurysm
  • Angle less than 60° relative to the axis of the suprarenal aorta
  • Minimum branch vessel diameter greater than 5 mm
  • Iliac artery distal fixation site greater than 10mm in length and diameter in the range of 8-21mm.

Exclusion criteria

  • Under the age of 18 years
  • Can be treated in accordance with the instructions for use with a legally marketed endovascular prosthesis
  • Is eligible for enrollment in a manufacturer-sponsored IDE at the investigational site
  • Willing to participate in a sponsor-investigator IDE with access to a non-physician modified endovascular prostheses at the investigational site
  • Willing to travel to an investigational site with access to a non-physician modified endovascular prosthesis
  • Unwilling or unable to comply with the follow-up schedule
  • Inability or refusal to give informed consent by patient or legal representative
  • Patient is pregnant or breastfeeding
  • Life expectancy < 2-years despite successful aneurysm exclusion
  • Free rupture with hemodynamic instability
  • Ongoing infection
  • Diagnosis of, or suspected connective tissue disease
  • Known sensitivities or allergies to the materials of construction of the devices
  • Known hypersensitivity or contraindication to anticoagulation or contrast media that cannot be adequately medically managed
  • Uncorrectable coagulopathy
  • Body habitus that would inhibit x-ray visualization of the aorta or exceeds the safe capacity of the equipment
  • Patient has had a major surgical or interventional procedure unrelated to the treatment of the aneurysm planned ≤ 30 days of the endovascular repair
  • Unstable angina (defined as angina with a progressive increase in symptoms, new onset at rest or nocturnal angina)
  • Systemic or local infection that may increase the risk of endovascular graft infection
  • Leaking or free rupture of aneurysm associated with hemodynamic instability.
  • Baseline creatinine greater than 3.0 mg/dL
  • Known history of, or suspected connective tissue disorders (e.g., Marfan Syndrome, Ehler's Danlos Syndrome)

Anatomical exclusion criteria:

  • Inadequate femoral or iliac access compatible with the required delivery systems, not amenable to open surgical or endovascular conduit placement
  • Absence of a non-aneurysmal aortic segment for proximal seal zone with:
  • A diameter measured outer wall to outer wall of no greater than 38mm and no less than 21 mm;
  • Parallel aortic wall with <20% diameter change and without significant calcification and/or thrombus in the selected area of seal zone
  • Visceral vessel anatomy not compatible with physician-modified Zenith® Alpha Endovascular Graft due to excessive occlusive disease or small size not amenable to stent graft placement
  • Unsuitable distal iliac artery fixation site and anatomy:
  • Common iliac artery fixation site diameter measured outer wall to outer wall on a sectional image (CT) <8.0 mm with inability to perform open surgical conduit
  • Iliac artery diameter measured outer wall to outer wall on a sectional image (CT) >21 mm at distal fixation site, with inability to perform open internal iliac artery revascularization or iliac branch stent graft
  • Iliac artery distal fixation site <10 mm in length
  • Inability to preserve at least one hypogastric artery

Treatment and study plan

Physician-Modified Cook Zenith Alpha Thoracic Endovascular Graft

Device

Cook Zenith® Alpha Thoracic Endovascular Graft will be modified to allow for the maintenance of blood flow into the visceral and renal branch vessels.

Primary outcomes

  1. Freedom from Major Adverse Events (MAE) at 30 days

    Time frame: 30 days

    Major Adverse Events include: Death, Bowel Ischemia, myocardial infarction, paraplegia/paraparesis, renal failure, respiratory failure, and stroke

  2. Proportion of study subjects with treatment success at 1 year

    Time frame: 1 year

    Treatment success is defined as a composite of technical success and freedom from the following:

    • Aneurysm enlargement [i.e., >5mm) as compared to a preoperative CT measure using orthogonal (i.e, perpendicular to the centerline) measurements]
    • Aneurysm rupture
    • Aneurysm-related mortality
    • Conversion to open repair
    • Secondary intervention for migration, Type I and III endoleaks, device integrity failure (e.g., fracture), and patency-related events (i.e., device component stenosis or occlusion and embolic events)
  3. Technical success

    Time frame: 1 year

    Technical success is defined as:

    • Successful delivery (i.e., ability to deliver the implant to the intended implantation site, without the need for unanticipated corrective intervention related to delivery) and deployment of the device at the intended location,
    • Patency of all endovascular graft and branch stent components
    • Absence of device deformations requiring unplanned placement of an additional device
    • Absence of inadvertent covering of aortic branch vessels
    • Successful withdrawal (i.e., successful withdrawal of the delivery system, without need for unanticipated corrective intervention related to withdrawal)

Secondary outcomes

  1. Quality of Life measures

    Time frame: 30 days, 6 months; 1, 2, 3, 4 and 5 years

    Questionnaire using SF - 36™ Health Survey

Sponsors and collaborators

Lead sponsor

Medstar Health Research Institute

Other

Registry information

Official study title

Clinical Outcomes, Radiation Dosage, and Quality of Life in Patients Treated With Fenestrated Stent Grafts for Complex Thoracoabdominal and Abdominal Aortic Aneurysms, Thoracoabdominal Aortic Aneurysms Secondary to Aortic Dissections

Important dates

Study start
2021
Primary completion
2028
Study completion
2028
First posted
Aug 26, 2020
Registry last updated
Aug 11, 2026

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.