Skip to main content
OpenTrials
Withdrawn

NCT Number: NCT04040673

RAman For Thyroid cancER

Ex vivo vibrational spectroscopy (VS), including Raman spectroscopy (RS) of thyroid tissue samples, collected from patients undergoing routine diagnostic thyroid biopsies for diagnosis of potential thyroid cancer. Raman spectra are to be correlated with consensus histopathology and clinical outcomes. Multivariate analysis to be used to evaluate the classification accuracy of VS ex vivo.

Why the study stopped: Covid19 halted study
Withdrawn

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Observational

Primary location

Biophotonics Research Unit

Gloucester, Gloucestershire, GL1 2AF, United Kingdom

About this study

The Investigators (The Biophotonics Research Unit, University of Exeter and University of Bristol) have developed these "smart needle" probes, consisting of fibre-optics within a fine needle for investigating cancer below the skin's surface. It is difficult to create a sensitive probe to fit inside a needle; however, The Investigators have demonstrated this approach in lymph node tissue samples from 68 patients in the laboratory, where The Investigators showed that our probe could detect cancer with a high level of accuracy.

Following on from our success with lymph nodes The Investigators wish to trial our smart needle on excised thyroid to demonstrate the device in another ENT cancer. Earlier studies have shown that thyroid cancer can be diagnosed using RS under a microscope with an accuracy greater than 78%.9 By eliminating the need for unnecessary surgery by diagnosis with our device, The Investigators will minimise the risk to patients, eliminate delays in obtaining results and reduce the cost of surgery and overnight stay in the hospital. The Investigators wish to advance this device closer to the clinic for a new cancer to improve the patient care pathway and remove the need for unnecessary surgery, by facilitating the work of the one-stop ENT diagnostic outpatient clinics.

The study consists of measuring spectra of new tissue taken during routine diagnostic surgical thyroid lobectomy.

New tissue for this project will be collected during routine biopsy will be rapidly analysed by a spectrometer before proceeding with conventional histopathological analysis. The new tissue will consist of thyroid and adjacent tissue biopsies. No additional tissue will be taken for this research, The Investigators only plan to measure samples taken during routine diagnosis in under 5 minutes, before passing the sections back to the surgical team for routine histopathological analysis.

Anonymous background information relevant to known risk factors, family history and details of any treatment, menopausal status, details relevant medical procedures, and any treatment for thyroid cancer will be provided with the samples. An example of the report can be found in Appendix 3. Tissue specimens taken during routine clinical care are to be subjected to ex vivo vibrational spectroscopic analysis immediately prior to being sent for routine histopathological analysis. Vibrational spectra are to be correlated with consensus histopathology of adjacent sections. Multivariate analysis is to be used to evaluate the classification accuracy of VS ex vivo. The vibrational spectra will be assessed for both prognostic as well as diagnostic information.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Patients undergoing routine diagnostic thyroid biopsy at surgery

Exclusion criteria

  • Patients are unable to provide informed consent.
  • Patients not attending for standard diagnostic biopsy for thyroid cancer

Treatment and study plan

Thyroid lobectomy

Procedure

routine surgical removal of thyroid for biopsy

Other names: thyroid nodule removal

Raman spectroscopy probe measurement

Device

The measurement of Raman spectra from the excised tissue

Primary outcomes

  1. Test the Raman needle probe on freshly exised tissue

    Time frame: 1 year

    Measure Raman spectra and match with histopathology. Perform leave-one-out analysis to measure performance of diagnosis of Raman spectroscopy

Secondary outcomes

  1. Calculate diagnostic performance of Raman spectroscopy probe for thyroid cancer

    Time frame: 1 year

    Diagnostic performance (specificity and sensitivity) of Raman spectroscopy (RS) for differentiation of thyroid cancer vs normal benign (no cancer).

    Diagnostic performance of RS for differentiation of thyroid cancer types.

    • Papillary thyroid cancer
    • Follicular thyroid cancer
    • Anaplastic thyroid cancer
    • Medullary thyroid cancer

Sponsors and collaborators

Lead sponsor

Gloucestershire Hospitals NHS Foundation Trust

Other

Registry information

Official study title

Evaluation of the Role of Vibrational Spectroscopy in the Diagnosis of Premalignant and Malignant Disease of the Thyroid RAFTER (RAman For Thyroid cancER)

Acronym: RAFTER

Important dates

Study start
2024
Primary completion
2025
Study completion
2025
First posted
Aug 1, 2019
Registry last updated
Sep 17, 2026

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.