Left Ventricular Physiological Effects of Veno-Arterial Extracorporeal Membrane Oxygenation Support During Cardiogenic Shock
NCT05426083
Acute Coronary Syndrome, Cardiogenic Shock
Minneapolis, Minnesota, United States
View Trial DetailsNCT Number: NCT02226523
To improve the sensitivity and specificity of immunoassay, the developing trends are to lower the detection threshold and to minimize the cross reaction. A new assay technology called immunomagnetic reduction (IMR) has been developed for rapid and on-site assay with small volume of sample. Rapid diagnosis of acute coronary syndrome (ACS) is a clinical and operational priority in busy emergency departments (ED), early and correct diagnosis is important. Cardiac enzymes (including CPK/CK-MB, troponins, myoglobulin) and electrocardiography (ECG) in combination with the medical history and physical examination are at present the diagnostic cornerstones. Novel biomarkers that rise earlier, have good diagnosis accuracy and have additional prognostic information are highly needed. The combination of multiple biomarker assays (markers of myocardial injury, inflammation/plaque ruptures or heart failure with different mechanism) may increase clinical sensitivity and improve early risk stratification. The present study, a rapid IMR assay with multiple biomarkers is proposed and we will examine the performance of this new investigational IMR assays, comparison with current commercial assays.
Looking for future studies?
Notify Me20 year–90 year
All sexes
Observational
Far Eastern Memorial Hospital, New Taipei City, Taiwan
To improve the sensitivity and specificity of immunoassay, the developing trends are to lower the detection threshold and to minimize the cross reaction. A new assay technology called immunomagnetic reduction (IMR) has been developed for rapid and on-site assay with very small volume of sample (i.e. less than 1ml whole blood). The reagent is a solution of homogeneously dispersed magnetic nanoparticles, which are coated with hydrophilic surfactants and bioprobes. Under external multiple alternating-current (ac) magnetic fields, magnetic nanoparticles oscillate with the multiple ac magnetic fields via magnetic interaction. The reagents under the external multiple ac magnetic fields show a magnetic property, called mixed-frequency ac magnetic susceptibility χac. Magnetic nanoparticles bind with the bioprobes on the outmost shell and become larger or clustered. The χac of the reagent is reduced, and the concentration of the biomolecules can be measured quantitatively. Several papers have demonstrated that IMR can be applied to assay proteins, viruses, chemicals, and nucleic acids once suitable bioprobes are immobilized onto the magnetic nanoparticles.
Rapid diagnosis of acute coronary syndrome (ACS) is a clinical and operational priority in busy emergency departments (ED). Since ACS is associated with a significant mortality and morbidity, early and correct diagnosis is of great importance. Chest pain is a frequent symptom in medical emergency departments and distinguishing patients with ACS within the chest pain group is a diagnostic challenge. Cardiac enzymes (including CPK/CK-MB, troponins, myoglobulin) and electrocardiography (ECG) in combination with the medical history and physical examination are at present the diagnostic cornerstones. Different cardiac enzymes are released after myocardial cell disintegration and are markers of cell necrosis, which might not be detected immediately after chest pain; and repeated measurements are suggested. Therefore novel biomarkers that rise earlier, have good diagnosis accuracy and have additional prognostic information are highly needed. Some publications address the potential benefit of the combination of multiple biomarker assays (markers of myocardial injury, inflammation/plaque ruptures or heart failure with different mechanism) could substantially increase clinical sensitivity and improve early risk stratification. However, this approach is rather time-consuming and not cost-effect. In the present study, a rapid IMR assay with multiple biomarkers is proposed and we will examine the performance of this new investigational IMR assays, comparison with current commercial assays.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
none
Time frame: 7 days
Evaluation of the diagnostic performance of rapid IMR assays in detection of acute myocardial infarction; Cardiac enzymes (CPK/CK-MB, troponins), electrocardiography in combination with the symptoms of typical chest pain are at present the diagnostic gold standard.
Time frame: 7 days
Compared to cardiac enzymes (CK/CK-MB, troponin), the diagnostic performance of combination of new biomarkers (BNP, FABP4, CRP, etc.) in detection of ACS by rapid IMR system
Time frame: 6 months
Evaluation of prognostic significance of multi-antibody-activated magnetic nanoparticles system (troponin, CK-MB, myoglobin, BNP, CRP, adipocyte fatty-acid binding protein/FABP-4) in acute coronary syndrome
Far Eastern Memorial Hospital
Other
The Development and Clinical Application of Rapid Assays Using Multi-antibody-activated Magnetic Nanoparticles System in Acute Coronary Syndrome
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05426083
Acute Coronary Syndrome, Cardiogenic Shock
Minneapolis, Minnesota, United States
View Trial DetailsNCT05514938
Acute Coronary Syndrome, Arterial Occlusive Diseases
Dallas, Texas, United States
View Trial DetailsNCT05699642
Acute Coronary Syndrome, Behavior
Boston, Massachusetts, United States
View Trial DetailsNCT05853042
Acute Coronary Syndrome, Acute Myocardial Infarction
Minneapolis, Minnesota, United States
View Trial Details