NCT Number: NCT06264830

3D Visualization System in Highly Myopic Cataract Operation

This study aims to investigate the impact of depth of field differences between the use of the 3D imaging system (NGENUITY® 3D Visualization System, Alcon, TX, USA) and conventional optical microscope in cataract surgery for highly myopic patients on intraoperative parameters and outcomes.

Recruiting

Interested in participating?

Request Info

Key information

Age range

20 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

About this study

The objective of this study is to compare the surgical outcomes and parameters between cataract surgeries performed using the NGENUITY® 3D Visualization System (Alcon, TX, USA), a 3D imaging system, and the current standard binocular microscope in highly myopic patients. The focus is on evaluating the differences in depth of field and their impact on intraoperative parameters and outcomes.

This prospective randomized controlled trial aims to enroll patients with both high myopia and cataracts requiring surgical intervention. Participants will be randomly assigned to undergo cataract surgery using the current standard binocular microscope (control group) or the NGENUITY® 3D Visualization System (Alcon, TX, USA) (study group). The study will compare intraoperative parameters, surgical outcomes, and the incidence of potential complications, including the frequency of microscope adjustments during surgery, total distance of adjustments during surgery, distance needed to achieve clear focus from the corneal surface to the posterior capsule, surgical duration, cumulative ultrasound energy during surgery, and occurrence of surgical complications.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • High myopia (axial length of 26 millimeters or more).
  • Presence of clinically significant age-related nuclear cataract requiring surgery, assessed using the International Classification System for Cataract (Lens Opacities Classification System III, LOC III), with a graded score indicating nuclear cataract (LOC III NC/NO grade 3-5).
  • Participants must be 20 years of age or older.

Exclusion criteria

  • The target eye has undergone vitrectomy surgery.
  • The target eye has undergone corneal refractive surgery.
  • Presence of corneal diseases such as corneal dystrophy, corneal trauma, corneal scarring, corneal ulcers, or clinically significant corneal softening that significantly affects the clarity of cataract surgery.
  • Complicated cataracts with features such as extreme hardness, complex composition, zonular laxity, lens dislocation, extensive capsular fibrosis, or those falling under the international cataract classification standards LOCIII NO/NC6 or C4-C5 or P4-P5.
  • Presence of other non-myopia-related eye diseases significantly affecting the complexity of surgery, such as adhesive uveitis causing adhesions, corneal damage due to trauma or lens dislocation, structural changes and adhesions due to intraocular inflammation, or severe uncorrected strabismus affecting eye alignment.

Treatment and study plan

Alcon-NGENUITY®(NG)-system

Device

During operation, the Alcon NGENUITY® (NG) System is mounted on microscope, while the surgeon will wear 3D glasses, watch 3D screen, and perform operation

Standard cataract operation

Procedure

Standard, modern cataract extraction with standard phacoemulsification technique, and posterior chamber intraocular lens implantation.

Primary outcomes

  1. Number of times of Microscopic focus adjustment, measured by counting from the video recordings

    Time frame: Throughout operation

    A video recorder will focus on the sliding joint between main suspension arm of microscope and its lens system. Once the surgeon change the focus, the marks on both side of the joint will change their relative positions. The times of changes will be counted from the video recording.

  2. Total moving distance in millimeter of microscope-lens-system relative to suspension arm, measured by ruler set on microscope

    Time frame: Throughout operation

    On the microscope one ruler will place on the suspension arm of microscope just beside the sliding joint of main optic lens system. On the side of main optic lens system, there will be a mark. When the surgeon change the focus of microscope. The mark will change its position relative to the ruler with millimeter in scale. The total moving distance is the add-ups of all changes during operation in absolute value.

  3. Distance of subjective focus change in millimeter between corneal surface and surface of posterior capsule, measured by ruler set on microscope

    Time frame: During the operation, immediately after lens material is removed, and immediately before the intraocular lens is implanted.

    On the microscope one ruler will place on the suspension arm of microscope just beside the sliding joint of main optic lens system. On the side of main optic lens system, there will be a mark. When the surgeon change the focus of the microscope. The mark will change its position relative to the ruler with millimeter in scale. Distance in millimeter of subjective focus between corneal surface and surface of posterior capsule can thus be measured.

Secondary outcomes

  1. Total operation time

    Time frame: Throughout operation

    Total operation time

  2. Cumulative dissipated energy (CDE) of phacoemulsification, that is automatically measured and demonstrated on the screen of phacoemulsification machine (Centurion)

    Time frame: Throughout operation

    Cumulative dissipated energy (CDE) is defined as mean phaco power times phaco time. CDE will be automatically measured and calculated by the Alcon centurion phacoemulsification machine, and will be demonstrated on the screen of the machine. CDE is itself the unit. The lower the CDE for an operation, the better.

  3. Number of Participants with intraoperative complication

    Time frame: Throughout operation

    Number of Participants with intraoperative complication

  4. Best-corrected visual acuity of the operated eye of Participants at each postoperative follow-up within 3 month, measured with Snellen chart under standard condition (6 meters in distance and standard illumination of environment)

    Time frame: Within 3 month after operation, at postoperative day1, at postoperative week 1, at post operative month 1, at post operative month 3

    The best-corrected visual acuity (BCVA) measured with Snellen chart is expected to range from 20/20(1.0) to 20/400(0.05). The refraction of the eye will be carefully corrected using trial lens. The higher the Snellen-chart value, and better the vision. For worse vison. The BCVA will be documented with able to count finger at certain distance ( such as100 centimeter or 30 centimeter). For even worse one, the BCVA will be documented with able to tell hand waving or not at certain distance ( such as100 centimeter or 30 centimeter). For even worse one, the BCVA will be documented with light perception or no light perception.

  5. Number of Participants with post-operative complication

    Time frame: Within three month after operation, at postoperative day1, at postoperative week 1, at post operative month 1, at post operative month 3

    Number of Participants with post-operative complication

  6. Intraocular pressure of the operated eye of participants at each postoperative follow-up within 3 month, measured with pneumatic tonometer

    Time frame: Within 3 month after operation, at postoperative day1, at postoperative week 1, at post operative month 1, at post operative month 3

    The intraocular pressure will be measured with pneumatic tonometer

Study contacts

Contact information is provided by the study sponsor or research team.

Cheng-Yung Lee, M.D.

CONTACT

[email protected]

886-2-23123456 ext. 65190

Tzyy-Chang Ho, M.D.

CONTACT

[email protected]

886-2-23123456 ext. 65190

Sponsors and collaborators

Lead sponsor

National Taiwan University Hospital

Other

Collaborators

  • Alcon Research

Registry information

Official study title

Comparing the Effect of Depth of Focus Difference in High Myopic Patients Receiving Cataract Operations Between 3D Visualization System and Traditional Optical Microscope.

Acronym: 3D-HiMCO

Important dates

Study start
2024
Primary completion
2025
Study completion
2025
First posted
Feb 20, 2024
Registry last updated