NCT Number: NCT07613658
Purpose of the Study When a child loses a "baby" molar early due to a cavity or injury, the surrounding teeth can shift into the empty space. This often blocks the permanent adult tooth from growing in correctly. To prevent this, dentists use a small metal device called a space maintainer.
This study aims to find out which of three different types of space maintainers lasts the longest, is most comfortable for the child, and is most efficient for the dental office to provide.
The Three Study Groups
Children in this study are randomly assigned to one of three groups:
1. 3D-Printed Custom Group: The dentist takes a digital picture (scan) of the child's mouth instead of a traditional mold. A custom-fit appliance is then 3D-printed using a specialized, medical-grade clear material. 2. Conventional Band-and-Loop Group: This is the traditional method. The dentist takes a physical mold of the teeth, which is sent to a laboratory. The child usually has to return for a second appointment a week later to have the metal appliance glued into place. 3. Denovo Chairside Group: This uses a kit of pre-made metal parts. The dentist selects the best fit and assembles the appliance right at the chairside, allowing it to be placed during a single visit.
What is Being Measured?
Researchers are following the children for 12 months to track:
Survival: Which appliance stays glued in and doesn't break most effectively?
Time: How much time does the dentist spend making and fitting the appliance?
Comfort: How much discomfort or pain did the child feel during the process?
Health: Does the appliance cause any irritation to the gums or surrounding teeth?
Who Can Participate? The study includes children between the ages of 5 and 10 who have lost at least one primary (baby) molar early and need a space maintainer to protect their future adult smile.
Importance of This Research By comparing these three methods, this study helps dentists understand if newer technologies, like 3D printing or pre-made kits, are better or more convenient than the traditional lab-made metal loops used for decades. This information will help families choose the best treatment for their children.
Trial opening soon.
Get Notified5 year–10 year
All sexes
Interventional
Not applicable
Buraidah, Al-Qassim Region, 52571, Saudi Arabia
Clinical Workflow and Device Fabrication
The trial compares three distinct manufacturing and clinical delivery pathways for pediatric space maintenance:
Data Acquisition: Digital impressions are captured using a high-precision intraoral scanner (3Shape TRIOS).
Design Phase: The STL files are imported into CAD software (exocad), where a custom space maintainer is designed with a specific focus on anatomical adaptation to the abutment tooth and the edentulous ridge.
Manufacturing: Appliances are fabricated via Stereolithography (SLA) using a Form 3B+ printer with BioMed Clear Resin. Post-processing includes a 20-minute isopropyl alcohol wash and 60 minutes of UV curing at 60°C to ensure biocompatibility and optimal mechanical properties.
Delivery: The printed appliance is bonded using a light-cured orthodontic adhesive.
Clinical Phase: Traditional alginate impressions are taken and poured with dental stone to create a physical working model.
Laboratory Phase: A stainless steel band (3M Unitek) is fitted to the abutment tooth on the model. A 0.036-inch stainless steel wire is contoured to the ridge and silver-soldered to the band.
Delivery: The appliance is polished and cemented in a subsequent clinical appointment using glass ionomer cement.
Selection: A prefabricated kit (Denovo Dental) is used to select a band size that fits the abutment tooth.
Assembly: A pre-formed wire loop is selected and adjusted for length at the chairside. The loop is mechanically secured to the band using the system's specialized crimping and locking mechanism, eliminating the need for soldering or laboratory delays.
Delivery: The assembled appliance is cemented during the same appointment as the initial measurement.
Randomization and Standardization Participants are allocated 1:1:1 using a computer-generated randomization sequence. To ensure consistency, all clinical procedures-including tooth preparation, scanning, and cementation-are performed by a group of calibrated pediatric dentists following a standardized protocol. For the 3D-printed group, resin batches and printer calibration are monitored weekly to ensure material integrity.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
A digitally designed, monolithic space maintainer. The workflow involves an intraoral scan (3Shape TRIOS) and CAD design (exocad). The device is fabricated using stereolithography (SLA) technology (Formlabs Form 3B+) with BioMed Clear Resin. It is bonded to the abutment tooth using a light-cured orthodontic adhesive
The traditional clinical reference standard. It is fabricated using an analog workflow: an alginate impression is taken to create a stone model, a stainless steel band (3M Unitek) is fitted to the model, and a 0.036-inch stainless steel wire is hand-contoured and silver-soldered to the band. The appliance is polished and cemented with glass ionomer cement.
A prefabricated, stainless steel space maintainer system (Denovo Dental) designed for immediate application. A pre-sized band is selected and fitted directly to the patient's tooth. A pre-formed wire loop is adjusted for length at the chairside and mechanically secured to the band using a specialized crimping and locking tool, requiring no laboratory soldering. It is cemented during the initial appointment.
Time frame: At 12 months from baseline
This measures the clinical longevity and "success" of the appliance. A "failure" is recorded if the appliance becomes completely or partially dislodged (cement failure), suffers a structural fracture, or causes significant soft-tissue trauma requiring its removal.
Time frame: At 12 month from baseline
Measured as the change in the mesiodistal dimension of the extraction space (in millimeters). Digital calipers or software will compare the initial space at baseline to the space remaining at the end of the study.
Time frame: At baseline
Researchers will record the active working time (in minutes) for each stage of fabrication. This includes chairside time (scanning or impressions and fitting) and laboratory time (3D printing and post-processing, manual soldering, or chairside assembly).
Time frame: Baseline, at 6 months, and at 12 months.
A clinical assessment of the soft tissue surrounding the abutment tooth. It will be scored from 0 (normal) to 3 (severe inflammation/bleeding) to determine if any material or design causes more irritation than others.
Contact information is provided by the study sponsor or research team.
Murad Alrashidi
Other
3D-Printed Custom Versus Conventional Band-and-Loop Versus Chairside Denovo Space Maintainers in the Primary Dentition: A Randomized Controlled Trial Protocol
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06965777
Dental Arch Development, Mouth Diseases
Cairo, Egypt
View Trial DetailsNCT07730944
Malocclusion, Mouth Diseases
Najran, Najran Region, Saudi Arabia
View Trial DetailsNCT07593378
Space Maintenance
Alexandria, Egypt
View Trial DetailsNCT07591324
Anxiety Disorders, Gingival Health
Ismailia, Ismailia Governorate, Egypt
View Trial Details