Intracavitary brachytherapy for gynaecological cancer currently use cylinder-type applicators or custom wax moulds to place a radioactive source in close proximity to the treatment area and provide highly conformal dose distributions. This study is a Phase IIa non-randomised interventional pilot trial that will investigate the feasibility of successfully treating patients with 3D-printed custom applicators.
Interested in participating?
Request Info18 year and older
Female
Interventional
Not applicable
St Leonards, New South Wales, 2067, Australia
Location status: Recruiting
Carol Kwong
CONTACT
Heidi Tsang
CONTACT
Intracavitary brachytherapy for gynaecological cancer currently use cylinder-type applicators or custom wax moulds to place a radioactive source in close proximity to the treatment area and provide highly conformal dose distributions. Current workflows for designing and constructing custom applicators with wax moulds are complex, time consuming and can result in a device that fails to meet original design specifications dictated by the planning system. In contrast, 3D-printed custom applicators provide the ability to design and print patient-specific devices that match optimal design specifications. The workflow for 3D-printed applicators is also more efficient with lower turn-around time and labour/equipment costs, and ensures a more robust product for treatment. Despite these advantages there is currently no radiotherapy department offering 3D printed custom applicators at present. This study will investigate the feasibility of successfully treating gynaecological cancers with 3D-printed custom applicators.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
3D-printed custom applicator
Time frame: 5 years
To demonstrate the feasibility of successfully simulating, planning and treating a HDR BT gynaecological patient with a 3D-printed internal mould, such that there is a dosimetric and/or clinical benefit for the patient relative to the current standard of care (cylindrical vaginal applicator). Successful treatment indicated by achieving no adverse events or difference to standard of care, and dosimentic comparisons of the 3D printed applicator plan to the cylinder plan are equivalent or better. Feasibility also determined by achieving no logistical or design issues in using the 3D printed applicators clinically.
Time frame: 5 years
RT acute and late side effects will be assessed and quantified using CTCAE criteria via clinician assessment and PROs
Time frame: 5 years
The plan quality of treatment plans generated for 3D-printed moulds and cylindrical applicators will be compared using dosimetric indices including target coverage (D90, Dose Homogeneity index) and organs at risk doses (D2cc, D1cc and point max) as well as patient comfort. statistical analysis (p-value) and comparison with international guidelines will be used to assess the quality of the treatment plans.
Time frame: 5 years
Feasibility of a pre-planned MR-only procedure will be determined using any of the patients that are accrued to the study who have both a CT and MRI performed at the time of simulation. The applicator and treatment plan will be generated based on the MRI and both compared to the CT-based plan and applicator. Feasibility will be indicated by generating equivalent plan quality and applicators from both methods.
Time frame: 5 years
The initial and final CT plan dosimetry will be compared to determine the feasibility of an initial CT-only process. Clinically insignificant differences between the plan dosimetry metrics and all within clinical tolerances will be used to quantify the difference. statistical analysis (p-value) will be used to assess the quality of the treatment plans.
Time frame: 5 years
The feasibility of an optimised 3D-printed applicator design based on the cylinder fitting procedure will be assessed by comparison of the 3D-printed clinical applicators with applicators derived from CT/MR of the vault in a relaxed state with an expansion applied based on the size of the cylinder applied in the fitting procedure. Feasibility will be determined by looking for a correlation between the size of the 3D printed clinical applicators and the size of the cylinders tolerated by the patient in the fitting procedure.
Time frame: 5 years
Procedure times will be recorded as per ARIA carepath tasks and time taken within the 3D-printed custom applicator workflow compared to the standard of care cylinder applicator workflow with equivalent or less time taken deemed acceptable
Time frame: 5 years
Costs associated with the 3D-printed design process will be defined and compared with the standard of care process via economic analysis of the resourcing and unit-price estimates in each arm of the respective workflows
Time frame: 5 years
Patient experience and acceptability of the 3D-printed simulation and treatment processes will be assessed with the EORTC QLQ-C30 questionnaires and success measured by comparison with the standard of care vaginal cylinder process. Questionnaires include questions with a scale of 1-4 where a higher number indicates a worse experience and a scale of 1-7 where a lower number indicates a worse experience.
Contact information is provided by the study sponsor or research team.
Jeremy Booth, PhD QMP
CONTACT
Marita Morgia, MD
CONTACT
Royal North Shore Hospital
Other
Study of 3D-printed Custom Applicators for Intracavitary HDR Gynaecological Brachytherapy (DISCO)
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06677190
Adnexal Diseases, Cervical Cancer
Boston, Massachusetts, United States
View Trial DetailsNCT06284343
Adnexal Diseases, Cancer-associated Thrombosis
Rome, Italy
View Trial DetailsNCT07702721
Adnexal Diseases, Cervical Cancer
View Trial DetailsNCT04122235
Adnexal Diseases, Alzheimer Disease
Gjøvik, Oppland, Norway
View Trial Details